» Articles » PMID: 17826323

Assessment of Myocardial Perfusion by Dynamic O-15-labeled Water PET Imaging: Validation of a New Fast Factor Analysis

Overview
Journal J Nucl Cardiol
Date 2007 Sep 11
PMID 17826323
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Factor analysis (FA) is an established method for separating myocardium from blood pool by use of oxygen 15-labeled water and positron emission tomography for analyzing myocardial blood flow (MBF). Conventional FA methods generating images from sinograms (sinoFA) are time-consuming, whereas FA can be performed on the reconstructed images (reconFA) in a fraction of time. We validated the MBF values obtained by reconFA versus sinoFA.

Methods And Results: In 23 volunteers (mean age, 26.6 +/- 3.4 years) MBF was calculated from sinoFA and reconFA and blindly reanalyzed 1 month later by the same observer. Intraobserver agreement and reconFA-versus-sinoFA agreement were assessed according to Bland and Altman (BA). Reproducibility proved excellent for global sinoFA (r = 0.968; P < .001; BA limits, -0.617 to 0.676 mL x min(-1) x g(-1)) and slightly superior for reconFA (r = 0.979; P < .001; BA limits, -0.538 to 0.558 mL x min(-1) x g(-1)), with wider limits of agreement for segmental MBF from sinoFA (r = 0.777; P < .001; BA limits, -1.676 to 1.656 mL x min(-1) x g(-1)) and reconFA (r = 0.844; P < .001; BA limits, -1.999 to 1.992 mL x min(-1) x g(-1)). In addition, sinoFA and reconFA showed excellent correlation (r = 0.975, P < .001) and agreement (BA limits, -0.528 to 0.648 mL x min(-1) x g(-1)) for global and segmental values (r = 0.955; P < .001; BA limits, -1.371 to 1.491 mL x min(-1) x g(-1)).

Conclusions: Use of reconFA allows rapid and reliable quantitative MBF assessment with O-15-labeled water.

Citing Articles

Simultaneous N-Ammonia and gadolinium first-pass myocardial perfusion with quantitative hybrid PET-MR imaging: a phantom and clinical feasibility study.

Nazir M, Gould S, Milidonis X, Reyes E, Ismail T, Neji R Eur J Hybrid Imaging. 2019; 3(1):15.

PMID: 31544170 PMC: 6718374. DOI: 10.1186/s41824-019-0062-6.


15-O-water myocardial flow reserve PET and CT angiography by full hybrid PET/CT as a potential alternative to invasive angiography.

Thomassen A, Braad P, Pedersen K, Petersen H, Johansen A, Diederichsen A Int J Cardiovasc Imaging. 2018; 34(12):2011-2022.

PMID: 30066164 DOI: 10.1007/s10554-018-1420-3.


Multimodality quantitative assessments of myocardial perfusion using dynamic contrast enhanced magnetic resonance and O-labelled water positron emission tomography imaging.

Papanastasiou G, Williams M, Dweck M, Mirsadraee S, Weir N, Fletcher A IEEE Trans Radiat Plasma Med Sci. 2018; 2(3):259-271.

PMID: 30003181 PMC: 6037289. DOI: 10.1109/TRPMS.2018.2796626.


SPECT and PET imaging of angiogenesis and arteriogenesis in pre-clinical models of myocardial ischemia and peripheral vascular disease.

Hendrikx G, Voo S, Bauwens M, Post M, Mottaghy F Eur J Nucl Med Mol Imaging. 2016; 43(13):2433-2447.

PMID: 27517840 PMC: 5095166. DOI: 10.1007/s00259-016-3480-8.


Advanced tracers in PET imaging of cardiovascular disease.

Li Y, Zhang W, Wu H, Liu G Biomed Res Int. 2014; 2014:504532.

PMID: 25389529 PMC: 4214169. DOI: 10.1155/2014/504532.


References
1.
Morita K, Tsukamoto T, Naya M, Noriyasu K, Inubushi M, Shiga T . Smoking cessation normalizes coronary endothelial vasomotor response assessed with 15O-water and PET in healthy young smokers. J Nucl Med. 2006; 47(12):1914-20. View

2.
Chareonthaitawee P, Kaufmann P, Rimoldi O, Camici P . Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans. Cardiovasc Res. 2001; 50(1):151-61. DOI: 10.1016/s0008-6363(01)00202-4. View

3.
Lee J, Lee D, Ahn J, Yeo J, Cheon G, Kim S . Generation of parametric image of regional myocardial blood flow using H(2)(15)O dynamic PET and a linear least-squares method. J Nucl Med. 2005; 46(10):1687-95. View

4.
Bergmann S, Fox K, RAND A, McElvany K, Welch M, Markham J . Quantification of regional myocardial blood flow in vivo with H215O. Circulation. 1984; 70(4):724-33. DOI: 10.1161/01.cir.70.4.724. View

5.
Hermansen F, Ashburner J, Spinks T, Kooner J, Camici P, Lammertsma A . Generation of myocardial factor images directly from the dynamic oxygen-15-water scan without use of an oxygen-15-carbon monoxide blood-pool scan. J Nucl Med. 1998; 39(10):1696-702. View