Lens Injuries Induced by Occupational Exposure in Non-optimized Interventional Radiology Laboratories

Overview
Journal Br J Radiol
Specialty Radiology
Date 1998 Oct 15
PMID 9771383
Citations 46
Authors
Affiliations
Soon will be listed here.
Abstract

Several cases of ophthalmologically confirmed lens injuries, caused by occupational radiation exposure, have occurred in two X-ray rooms devoted to vascular and visceral interventional radiology procedures. Both laboratories were equipped with overcouch X-ray systems not designed for interventional radiology and without specific tools for radiation protection of the eyes. Typical workloads ranged from between two and five procedures per day. For the two radiologists affected, estimates for the dose to eye lens ranged from 450 to 900 mSv per year, over several years. Once the incidents had been detected, the X-ray systems in both rooms were removed and new equipment specifically designed for interventional radiology was installed, including suspended shielding screens. Since these lens injuries were only detected accidentally, measures to avoid similar occurrences in the future are discussed.

Citing Articles

Influence of Hospital Bed Count on the Positioning of Cardiovascular Interventional Radiology (IR) Nurses: Online Questionnaire Survey of Japanese IR-Specialized Radiological Technologists.

Kuriyama T, Moritake T, Hitomi G, Nakagami K, Morota K, Matsuzaki S Nurs Rep. 2025; 15(1).

PMID: 39852633 PMC: 11767440. DOI: 10.3390/nursrep15010011.


Background Factors Affecting the Radiation Exposure of the Lens of the Eye among Nurses in Interventional Radiology: A Quantitative Observational Study.

Kuriyama T, Moritake T, Nakagami K, Morota K, Hitomi G, Kitamura H Nurs Rep. 2024; 14(1):413-427.

PMID: 38391077 PMC: 10885035. DOI: 10.3390/nursrep14010032.


An In-depth Analysis of the Adverse Effects of Ionizing Radiation Exposure on Cardiac Catheterization Staffs.

Alvandi M, Javid R, Shaghaghi Z, Farzipour S, Nosrati S Curr Radiopharm. 2024; 17(3):219-228.

PMID: 38314600 DOI: 10.2174/0118744710283181231229112417.


Eye Lens Radiation Dose to Nurses during Cardiac Interventional Radiology: An Initial Study.

Yamada A, Haga Y, Sota M, Abe M, Kaga Y, Inaba Y Diagnostics (Basel). 2023; 13(18).

PMID: 37761370 PMC: 10528633. DOI: 10.3390/diagnostics13183003.


Image Quality and Radiation Dose of Conventional and Wide-Field High-Resolution Cone-Beam Computed Tomography for Cerebral Angiography: A Phantom Study.

Kawauchi S, Chida K, Hamada Y, Tsuruta W Tomography. 2023; 9(5):1683-1693.

PMID: 37736987 PMC: 10514806. DOI: 10.3390/tomography9050134.