Accuracy of Single-dipole Inverse Solution when Localising Ventricular Pre-excitation Sites: Simulation Study

Overview
Publisher Springer
Date 1998 Sep 25
PMID 9747572
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Different factors are investigated that may affect the accuracy of an inverse solution that uses a single-dipole equivalent generator, in a standardised inhomogeneous torso model, when localising the pre-excitation sites. An anatomical model of the human ventricular myocardium is used to simulate body surface potential maps (BSPMs) and magnetic field maps (MFMs) for 35 pre-excitation sites positioned on the epicardial surface along the atrioventricular ring. The sites of pre-excitation activity are estimated by the single-dipole method, and the measure for the accuracy of the localisation is the localisation error, defined as the distance between the location of the best-fitting single dipole and the actual site of pre-excitation in the ventricular model. The findings indicate that, when the electrical properties of the volume conductor and lead positions are precisely known and the 'measurement' noise is added to the simulated BSPMs and MFMs, the single-dipole method optimally localises the pre-excitation activity 20 ms after the onset of pre-excitation, within 0.71 +/- 0.28 cm and 0.65 +/- 0.30 cm using BSPMs and MFMs, respectively. When the standard torso model is used to localise the sites of onset of the pre-excitation sequence initiated in four individualised torso models, the maximum errors are as high as 2.6-3.0 cm (even though the average error, for both the BSPM and MFM localisations, remains within the 1.0-1.5 cm range). In spite of these shortcomings, it is thought that single-dipole localisations can be useful for non-invasive pre-interventional planning.

Citing Articles

The magnetocardiogram.

Roth B Biophys Rev (Melville). 2024; 5(2):021305.

PMID: 38827563 PMC: 11139488. DOI: 10.1063/5.0201950.


Equivalent moving dipole localization of cardiac ectopic activity in a swine model during pacing.

Lai D, Liu C, Eggen M, Iaizzo P, He B IEEE Trans Inf Technol Biomed. 2010; 14(6):1318-26.

PMID: 20515710 PMC: 2948591. DOI: 10.1109/TITB.2010.2051448.


Visualization of three-dimensional cardiac electrical excitation using standard heart model and anterior and posterior magnetocardiogram.

Ogata K, Kandori A, Miyashita T, Tsukada K, Nakatani S, Shimizu W Int J Cardiovasc Imaging. 2006; 22(3-4):581-93.

PMID: 16521045 DOI: 10.1007/s10554-005-9048-5.


Value and limitations of an inverse solution for two equivalent dipoles in localising dual accessory pathways.

Jazbinsek V, Hren R, Stroink G, Horacek B, Trontelj Z Med Biol Eng Comput. 2003; 41(2):133-40.

PMID: 12691432 DOI: 10.1007/BF02344880.


Classifying cases of fetal Wolff-Parkinson-White syndrome by estimating the accessory pathway from fetal magnetocardiograms.

Kandori A, Hosono T, Chiba Y, Shinto M, Miyashita S, Murakami M Med Biol Eng Comput. 2003; 41(1):33-9.

PMID: 12572745 DOI: 10.1007/BF02343536.


References
1.
Weismuller P, Abraham-Fuchs K, Schneider S, Richter P, Kochs M, Edrich J . Biomagnetic noninvasive localization of accessory pathways in Wolff-Parkinson-White syndrome. Pacing Clin Electrophysiol. 1991; 14(11 Pt 2):1961-5. DOI: 10.1111/j.1540-8159.1991.tb02798.x. View

2.
Hren R, Horacek B . Value of simulated body surface potential maps as templates in localizing sites of ectopic activation for radiofrequency ablation. Physiol Meas. 1997; 18(4):373-400. DOI: 10.1088/0967-3334/18/4/010. View

3.
Hren R, Zhang X, Stroink G . Comparison between electrocardiographic and magnetocardiographic inverse solutions using the boundary element method. Med Biol Eng Comput. 1996; 34(2):110-4. DOI: 10.1007/BF02520014. View

4.
Moshage W, Achenbach S, Gohl K, Bachmann K . Evaluation of the non-invasive localization accuracy of cardiac arrhythmias attainable by multichannel magnetocardiography (MCG). Int J Card Imaging. 1996; 12(1):47-59. DOI: 10.1007/BF01798116. View

5.
van Oosterom A, Huiskamp G . The effect of torso inhomogeneities on body surface potentials quantified using "tailored" geometry. J Electrocardiol. 1989; 22(1):53-72. DOI: 10.1016/0022-0736(89)90023-x. View