Magnetization Transfer Imaging of Rat Brain Under Non-steady-state Conditions. Contrast Prediction Using a Binary Spin-bath Model and a Super-lorentzian Lineshape

Overview
Journal J Magn Reson
Publisher Elsevier
Date 1998 May 2
PMID 9500906
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Magnetization transfer contrast imaging using turbo spin echo and continuous wave off-resonance irradiation was carried out on rat brain in vivo at 4.7 T. By systematically varying the off-resonance irradiation power and the offset-frequency, the signal intensities obtained under steady-state for both transverse and longitudinal magnetization were successfully analyzed with a simple binary spin-bath model taking into account a free water compartment and a pool of protons with restricted motions bearing a super-Lorentzian lineshape. Due to important RF power deposition, such experimental conditions are not practical for routine imaging on humans. An extension of the model was derived to describe the system for shorter off-resonance pulse duration, i.e., when the longitudinal magnetization of the free protons has not reached a steady-state. Data sets obtained for three regions of interest, namely the corpus callosum, the basal ganglia, and the temporal lobe, were correctly interpreted for off-resonance pulse durations varying from 0.3 to 3 s. The parameter sets obtained from the calculations made it possible to predict the contrast between the different regions as a function of the pulse power, the offset frequency, and pulse duration. Such an approach could be extended to contrast prediction for human brain at 1.5 T.

Citing Articles

Unraveling contributions to the Z-spectrum signal at 3.5 ppm of human brain tumors.

Heo H, Singh M, Mahmud S, Blair L, Kamson D, Zhou J Magn Reson Med. 2024; 92(6):2641-2651.

PMID: 39086185 PMC: 11436306. DOI: 10.1002/mrm.30241.


CEST and nuclear Overhauser enhancement imaging with deep learning-extrapolated semisolid magnetization transfer reference: Scan-rescan reproducibility and reliability studies.

Heo H, Singh M, Yedavalli V, Jiang S, Zhou J Magn Reson Med. 2023; 91(3):1002-1015.

PMID: 38009996 PMC: 10842109. DOI: 10.1002/mrm.29937.


Bloch simulator-driven deep recurrent neural network for magnetization transfer contrast MR fingerprinting and CEST imaging.

Singh M, Jiang S, Li Y, van Zijl P, Zhou J, Heo H Magn Reson Med. 2023; 90(4):1518-1536.

PMID: 37317675 PMC: 10524222. DOI: 10.1002/mrm.29748.


Only-train-once MR fingerprinting for B and B inhomogeneity correction in quantitative magnetization-transfer contrast.

Kang B, Singh M, Park H, Heo H Magn Reson Med. 2023; 90(1):90-102.

PMID: 36883726 PMC: 10149616. DOI: 10.1002/mrm.29629.


Quantitative chemical exchange saturation transfer imaging of nuclear overhauser effects in acute ischemic stroke.

Msayib Y, Harston G, Ray K, Larkin J, Sutherland B, Sheerin F Magn Reson Med. 2022; 88(1):341-356.

PMID: 35253936 PMC: 9314583. DOI: 10.1002/mrm.29187.