Abstract

Our objective was to design a structured approach to maintaining comparability of biochemical data during a long clinical trial. Maintaining the comparability of clinical and biochemical data obtained in long-term studies is essential, even though analytical methods in the laboratory may be changed, conventions on specimen handling and storage revised, calibration procedures updated, quality-control systems replaced, and secular changes may occur. The United Kingdom Prospective Diabetes Study (UKPDS), a large randomized control trial investigating therapy for type 2 diabetes, was the setting for the study. Data were collected from 5102 subjects randomized since 1977. Our techniques included quality control, external quality assurance, direct comparison of laboratory methods when updating assays and statistical techniques for the detection of unsuspected changes in assay bias, laboratory comparisons of new with old assay methodologies, the realigning of data to current methods, the use of a suitable reference population for long-term monitoring, and rules to aid decision-making about clinical vs statistical significance. Procedures by which comparability of data is assured should be specified for all long-term trials and, where possible, comparison with reference methods should be detailed to allow results from different laboratories to be compared.

Citing Articles

The Human Physiome: how standards, software and innovative service infrastructures are providing the building blocks to make it achievable.

Nickerson D, Atalag K, de Bono B, Geiger J, Goble C, Hollmann S Interface Focus. 2016; 6(2):20150103.

PMID: 27051515 PMC: 4759754. DOI: 10.1098/rsfs.2015.0103.


Multiple inflammatory biomarker detection in a prospective cohort study: a cross-validation between well-established single-biomarker techniques and an electrochemiluminescense-based multi-array platform.

van Bussel B, Ferreira I, van de Waarenburg M, van Greevenbroek M, van der Kallen C, Henry R PLoS One. 2013; 8(3):e58576.

PMID: 23472208 PMC: 3589355. DOI: 10.1371/journal.pone.0058576.


High prevalence of low plasma thiamine concentration in diabetes linked to a marker of vascular disease.

Thornalley P, Babaei-Jadidi R, Al Ali H, Rabbani N, Antonysunil A, Larkin J Diabetologia. 2007; 50(10):2164-70.

PMID: 17676306 PMC: 1998885. DOI: 10.1007/s00125-007-0771-4.


Additive effects of glycaemia and blood pressure exposure on risk of complications in type 2 diabetes: a prospective observational study (UKPDS 75).

Stratton I, Cull C, Adler A, Matthews D, Neil H, Holman R Diabetologia. 2006; 49(8):1761-9.

PMID: 16736131 DOI: 10.1007/s00125-006-0297-1.


Hemoglobin A1c measurements over nearly two decades: sustaining comparable values throughout the Diabetes Control and Complications Trial and the Epidemiology of Diabetes Interventions and Complications study.

Steffes M, Cleary P, Goldstein D, Little R, Wiedmeyer H, Rohlfing C Clin Chem. 2005; 51(4):753-8.

PMID: 15684277 PMC: 2635091. DOI: 10.1373/clinchem.2004.042143.