Plasma Viral Load and CD4+ Lymphocytes As Prognostic Markers of HIV-1 Infection
Overview
Authors
Affiliations
Background: The rate of disease progression among persons infected with human immunodeficiency virus type 1 (HIV-1) varies widely, and the relative prognostic value of markers of disease activity has not been defined.
Objective: To compare clinical, serologic, cellular, and virologic markers for their ability to predict progression to the acquired immunodeficiency syndrome (AIDS) and death during a 10-year period.
Design: Prospective, multicenter cohort study.
Setting: Four university-based clinical centers participating in the Multicenter AIDS Cohort Study.
Patients: 1604 men infected with HIV-1.
Measurements: The markers compared were oral candidiasis (thrush) or fever; serum neopterin levels; serum beta 2-microglobulin levels; number and percentage of CD3+, CD4+, and CD8+ lymphocytes; and plasma viral load, which was measured as the concentration of HIV-1 RNA found using a sensitive branched-DNA signal-amplification assay.
Results: Plasma viral load was the single best predictor of progression to AIDS and death, followed (in order of predictive strength) by CD4+ lymphocyte count and serum neopterin levels, serum beta 2-microglobulin levels, and thrush or fever. Plasma viral load discriminated risk at all levels of CD4+ lymphocyte counts and predicted their subsequent rate of decline. Five risk categories were defined by plasma HIV-1 RNA concentrations: 500 copies/mL or less, 501 to 3000 copies/mL, 3001 to 10000 copies/mL, 10001 to 30000 copies/mL, and more than 30000 copies/mL. Highly significant (P < 0.001) differences in the percentages of participants who progressed to AIDS within 6 years were seen in the five risk categories: 5.4%, 16.6%, 31.7%, 55.2%, and 80.0%, respectively. Highly significant (P < 0.001) differences in the percentages of participants who died of AIDS within 6 years were also seen in the five risk categories: 0.9%, 6.3%, 18.1%, 34.9%, and 69.5%, respectively. A regression tree incorporating both HIV-1 RNA measurements and CD4+ lymphocyte counts provided better discrimination of outcome than did either marker alone; use of both variables defined categories of risk for AIDS within 6 years that ranged from less than 2% to 98%.
Conclusions: Plasma viral load strongly predicts the rate of decrease in CD4+ lymphocyte count and progression to AIDS and death, but the prognosis of HIV-infected persons is more accurately defined by combined measurement of plasma HIV-1 RNA and CD4+ lymphocytes.
Gandla S, Nakka R, Khan R, Bose E, Ghebremichael M Trop Med Infect Dis. 2025; 10(1).
PMID: 39852675 PMC: 11768424. DOI: 10.3390/tropicalmed10010024.
Zhang Y, Otte F, Stoeckle M, Thielen A, Daumer M, Kaiser R PLoS Pathog. 2024; 20(9):e1012526.
PMID: 39292732 PMC: 11410260. DOI: 10.1371/journal.ppat.1012526.
Vardanega V, New E, Mezzio D, Eddowes L J Manag Care Spec Pharm. 2024; 30(9):1001-1012.
PMID: 39213144 PMC: 11365559. DOI: 10.18553/jmcp.2024.30.9.1001.
Leuthner M, Reisbeck M, Helou M, Hayden O Micromachines (Basel). 2024; 15(4).
PMID: 38675331 PMC: 11051966. DOI: 10.3390/mi15040520.
Khan N, Beg M, Sarwar M, Kyzy G, Zhetkinbekova T, Mamatov A Cureus. 2024; 16(2):e53451.
PMID: 38435229 PMC: 10909385. DOI: 10.7759/cureus.53451.