» Articles » PMID: 9107170

Estimation of Central Aortic Pressure Waveform by Mathematical Transformation of Radial Tonometry Pressure. Validation of Generalized Transfer Function

Overview
Journal Circulation
Date 1997 Apr 1
PMID 9107170
Citations 298
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Central aortic pressures and waveform convey important information about cardiovascular status, but direct measurements are invasive. Peripheral pressures can be measured noninvasively, and although they often differ substantially from central pressures, they may be mathematically transformed to approximate the latter. We tested this approach, examining intersubject and intrasubject variability and the validity of using a single averaged transformation, which would enhance its applicability.

Methods And Results: Invasive central aortic pressure by micromanometer and radial pressure by automated tonometry were measured in 20 patients at steady state and during hemodynamic transients (Valsalva maneuver, abdominal compression, nitroglycerin, or vena caval obstruction). For each patient, transfer functions (TFs) between aortic and radial pressures were calculated by parametric model and results averaged to yield individual TFs. A generalized TF was the average of individual functions. TFs varied among patients, with coefficients of variation for peak amplitude and frequency at peak amplitude of 24.9% and 16.9%, respectively. Intrapatient TF variance with altered loading (> 20% variation in peak amplitude) was observed in 28.5% of patients. Despite this, the generalized TF estimated central arterial pressures to < or = 0.2 +/- 3.8 mm Hg error, arterial compliance to 6 +/- 7% accuracy, and augmentation index to within -7% points (30 +/- 45% accuracy). Individual TFs were only marginally superior to the generalized TF for reconstructing central pressures.

Conclusions: Central aortic pressures can be accurately estimated from radial tonometry with the use of a generalized TF. The reconstructed waveform can provide arterial compliance estimates but may underestimate the augmentation index because the latter requires greater fidelity reproduction of the wave contour.

Citing Articles

A spectral machine learning approach to derive central aortic pressure waveforms from a brachial cuff.

Tamborini A, Aghilinejad A, Gharib M Proc Natl Acad Sci U S A. 2025; 122(9):e2416006122.

PMID: 40009644 PMC: 11892652. DOI: 10.1073/pnas.2416006122.


The acute effects of continuous and intermittent whole-body passive heating on cardiovascular disease risk indicators in healthy and young males and females.

Su Y, Martinkova A, ODonnell E, Bailey S, Leicht C Eur J Appl Physiol. 2025; .

PMID: 39953332 DOI: 10.1007/s00421-025-05718-0.


Comparison of Influence of Office and 24-h Central Aortic Blood Pressure on Target Organ Damage in Hypertension.

Hu Y, Yang H, Chang G, Bai Y, Avolio A, Wang Q J Clin Hypertens (Greenwich). 2025; 27(1):e14956.

PMID: 39821931 PMC: 11771776. DOI: 10.1111/jch.14956.


Association of Total Mortality and Cardiovascular Endpoints With the Timing of the First and Second Systolic Peak of the Aortic Pulse Wave.

Cheng Y, An D, Aparicio L, Huang Q, Yu Y, Sheng C J Clin Hypertens (Greenwich). 2025; 27(1):e14962.

PMID: 39821625 PMC: 11771774. DOI: 10.1111/jch.14962.


Diabetic Nephropathy-Associated Impaired Aortic Function Is Not Mediated by Mean Arterial Pressure and Its Determinants.

Hsu H, Mazibuko M, Robinson C, Dlongolo N, Woodiwiss A, Teckie G J Clin Med. 2025; 13(24.

PMID: 39768750 PMC: 11727795. DOI: 10.3390/jcm13247827.