» Articles » PMID: 8868988

Transcatheter Occlusion of the Arterial Duct with Cook Detachable Coils: Early Experience

Overview
Journal Heart
Date 1996 Sep 1
PMID 8868988
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To assess the effectiveness of modified, controlled release Gianturco coils for transcatheter occlusion of the arterial duct.

Design: Prospective study, approved by local medical ethics committee.

Setting: Tertiary paediatric cardiac centre.

Patients: 43 patients with left to right shunting through the arterial duct, two of whom had a residual leak after surgical ligation and three had residual shunting after previous Rashkind umbrella implantation.

Intervention: Transcatheter delivery of one or more coils to the arterial duct.

Main Outcome Measures: Complete occlusion of the arterial duct, based on intention to treat and judged by Doppler echocardiography. Absence of flow disturbance in the branch pulmonary arteries and the descending aorta following the procedure. Assessment of cost of the disposable items used.

Results: At a median follow up period of three months complete duct occlusion was achieved in 37 (86%) of the 43 patients. No flow disturbance in the branch pulmonary arteries or the descending aorta was detected in any patient. The median cost of disposable items used during the procedure was 342 pounds.

Conclusions: The Cook detachable coil is an effective and financially attractive alternative to the Rashkind umbrella for closure of the arterial duct.

Citing Articles

Patent ductus arteriosus closure using Occlutech Duct Occluder, experience in Port Elizabeth, South Africa.

Pepeta L, Greyling A, Nxele M, Makrexeni Z Ann Pediatr Cardiol. 2017; 10(2):131-136.

PMID: 28566820 PMC: 5431024. DOI: 10.4103/0974-2069.205144.


Patent ductus arteriosus with persistent pulmonary artery hypertension after transcatheter closure.

Feng J, Kong X, Sheng Y, Yang R Ther Clin Risk Manag. 2016; 12:1609-1613.

PMID: 27843323 PMC: 5098547. DOI: 10.2147/TCRM.S112400.


Ductal closure using the Amplatzer duct occluder type two: experience in Port Elizabeth hospital complex, South Africa: cardiovascular topic.

Pepeta L, Dippenaar A Cardiovasc J Afr. 2013; 24(6):202-7.

PMID: 23812377 PMC: 4986386. DOI: 10.5830/CVJA-2013-033.


To close or not to close: the very small patent ductus arteriosus.

Fortescue E, Lock J, Galvin T, McElhinney D Congenit Heart Dis. 2010; 5(4):354-65.

PMID: 20653702 PMC: 4240224. DOI: 10.1111/j.1747-0803.2010.00435.x.


Transcatheter closure of patent ductus arteriosus among native high-altitude habitants.

Szkutnik M, Menacho-Delgadillo R, Palmero-Zilveti E, Bialkowski J Pediatr Cardiol. 2007; 29(3):624-7.

PMID: 18094914 DOI: 10.1007/s00246-007-9174-z.


References
1.
. Transcatheter occlusion of persistent arterial duct. Report of The European Registry. Lancet. 1992; 340(8827):1062-6. View

2.
Fadley F, Al-Halees Z, Galal O, Kumar N, Wilson N . Left pulmonary artery stenosis after transcatheter occlusion of persistent arterial duct. Lancet. 1993; 341(8844):559-60. DOI: 10.1016/0140-6736(93)90321-7. View

3.
Lloyd T, Fedderly R, Mendelsohn A, Sandhu S, Beekman 3rd R . Transcatheter occlusion of patent ductus arteriosus with Gianturco coils. Circulation. 1993; 88(4 Pt 1):1412-20. DOI: 10.1161/01.cir.88.4.1412. View

4.
Verin V, Saveliev S, Kolody S, Prokubovski V . Results of transcatheter closure of the patent ductus arteriosus with the Botallooccluder. J Am Coll Cardiol. 1993; 22(5):1509-14. DOI: 10.1016/0735-1097(93)90564-h. View

5.
Moore J, George L, Kirkpatrick S, Mathewson J, Spicer R, Uzark K . Percutaneous closure of the small patent ductus arteriosus using occluding spring coils. J Am Coll Cardiol. 1994; 23(3):759-65. DOI: 10.1016/0735-1097(94)90765-x. View