» Articles » PMID: 8771283

The Utility of Isokinetic Dynamometry in the Assessment of Human Muscle Function

Overview
Journal Sports Med
Specialty Orthopedics
Date 1996 Jan 1
PMID 8771283
Citations 38
Authors
Affiliations
Soon will be listed here.
Abstract

Isokinetic dynamometry has become a favoured method for the assessment of dynamic muscle function in both clinical research and sports environments. Several indices, such as peak torque, are used in the literature to characterise individual, group or larger population performance via these sophisticated data acquisition systems. Research suggests that there are several competing demands on the design of the measurement protocol which may affect the measurement of isokinetic strength and subsequent suitability of data for meaningful evaluation and interpretation. There is a need to increase measurement rigour, reliability and sensitivity to a level which is commensurate with the intended application, via more elaborate multiple-trial protocols. However, this may be confounded by logistical and financial constraints or reduced individual compliance. The net effect of the interaction of such demands may be considered to be the utility of the isokinetic dynamometry protocol. Of the factors which impinge on utility, those which relate to reliability afford the most control by the test administrator. Research data suggest that in many measurement applications, the reliability and sensitivity associated with all frequently-used indices of isokinetic leg strength which are estimated via single-trial protocols, are not sufficient to differentiate either performance change within the same individual or between individuals within a homogeneous group. While such limitation may be addressed by the use of protocols based on 3 to 4 inter-day trials for the index of peak torque, other indices which demonstrate reduced reliability, for example the composite index of the ratio of knee flexion to extension peak torque, may require many more replicates to achieve the same level of sensitivity. Here, the measurement utility of the index may not be sufficient to justify its proper deployment.

Citing Articles

Isokinetic assessment of muscle function according to physical activity level and cardiovascular risk in asymptomatic adults aged 20 to 80 years.

Dourado V, Nascimento M, Navarro R, Silva R, Gonze B, Guedes K Braz J Med Biol Res. 2025; 58:e14214.

PMID: 40053040 PMC: 11884781. DOI: 10.1590/1414-431X2025e14214.


Multivariable analysis for predicting lower limb muscular strength with a hip-joint exoskeleton.

Kang B, Lee C, Kim D, Lee H, Lee D, Jeon H Front Bioeng Biotechnol. 2024; 12:1431015.

PMID: 39512653 PMC: 11540785. DOI: 10.3389/fbioe.2024.1431015.


Physical and Muscular Performance in a Professional Soccer Player with a Posterior Cruciate Ligament Injury Following an Isokinetic Exercise Program: A Case Report.

Mostagi F, Silva P, Munaro G, Marcato R, Nampo D, Santiago G Int J Sports Phys Ther. 2024; 19(10):1244-1254.

PMID: 39371189 PMC: 11446732. DOI: 10.26603/001c.123471.


Acute Dosing Strategy with Vistula Tart Cherries for Recovery of Strenuous Exercise-A Feasibility Study.

Squires E, Walshe I, Dodd A, Broadbelt E, Hayman O, McHugh M Nutrients. 2024; 16(16).

PMID: 39203845 PMC: 11357489. DOI: 10.3390/nu16162709.


Cut-off points for knee extension strength: identifying muscle weakness in older adults.

Zheng H, Sun W, Zhou Z, Tian F, Xiao W, Zheng L Eur Geriatr Med. 2024; 15(4):913-925.

PMID: 38926333 DOI: 10.1007/s41999-024-01009-7.


References
1.
Seger J, Westing S, Hanson M, Karlson E, Ekblom B . A new dynamometer measuring concentric and eccentric muscle strength in accelerated, decelerated, or isokinetic movements. Validity and reproducibility. Eur J Appl Physiol Occup Physiol. 1988; 57(5):526-30. DOI: 10.1007/BF00418457. View

2.
Narici M, Sirtori M, Mastore S, Mognoni P . The effect of range of motion and isometric pre-activation on isokinetic torques. Eur J Appl Physiol Occup Physiol. 1991; 62(3):216-20. DOI: 10.1007/BF00643745. View

3.
Kannus P . The relationship between peak torque and work of the quadriceps and hamstrings after knee injury. J Sports Med Phys Fitness. 1990; 30(2):185-9. View

4.
Beunen G, Borms J . Kinanthropometry: roots, developments and future. J Sports Sci. 1990; 8(1):1-15. DOI: 10.1080/02640419008732127. View

5.
Montgomery L, Douglass L, Deuster P . Reliability of an isokinetic test of muscle strength and endurance. J Orthop Sports Phys Ther. 1989; 10(8):315-22. DOI: 10.2519/jospt.1989.10.8.315. View