Is the Nucleus Pulposus a Solid or a Fluid? Mechanical Behaviors of the Nucleus Pulposus of the Human Intervertebral Disc

Overview
Specialty Orthopedics
Date 1996 May 15
PMID 8727192
Citations 91
Authors
Affiliations
Soon will be listed here.
Abstract

Study Design: A new technique to measure the viscoelastic behavior of the nucleus pulposus in shear was used to assess its solid and fluid characteristics.

Objectives: To review existing knowledge on mechanical behaviors of the nucleus pulposus, and to develop a new technique to study the viscoelastic behaviors of isolated nucleus pulposus samples in torsional (pure) shear under transient and dynamic conditions.

Summary Of Background Data: Numerous studies have investigated the swelling behavior of the nucleus and found the swelling pressure to range approximately 0.05-3 MPa, depending on loading conditions. Very few studies, however, have investigated the load-deformational behaviors of the nucleus pulposus.

Methods: Thirteen nondegenerate samples of nucleus pulposus were harvested from lumbar discs and tested in torsional shear under transient and dynamic test conditions. A linear viscoelastic law with variable amplitude relaxation and dynamic frequency sweep experiments. The coefficients of the viscoelastic law were determined from the stress relaxation experiments, whereas the dynamic shear modulus and phase shift angle were determined from the frequency sweep.

Results: The nucleus exhibits significant viscoelastic effects in shear. Under transient conditions, the stress relaxed to values near zero, which is indicative of the "fluid-like" behaviors of the nucleus. Under dynamic conditions, however, the material parameters for the nucleus, magnitude of the complex modulus (7-21 kPa), and phase angle (23-31 degrees) were more characteristic of a viscoelastic solid. The authors' proposed stress-strain law exhibited excellent agreement with the viscoelastic data.

Conclusions: In response to shear deformations, the nucleus pulposus exhibited significant viscoelastic effects, characteristic of a fluid and a solid. Whether the nucleus pulposus behaves more as a fluid or a solid in vivo depends on the rate of loading.

Citing Articles

Biomechanics of soft biological tissues and organs, mechanobiology, homeostasis and modelling.

Holzapfel G, Humphrey J, Ogden R J R Soc Interface. 2025; 22(222):20240361.

PMID: 39876788 PMC: 11775666. DOI: 10.1098/rsif.2024.0361.


[Biomechanics of the intervertebral disc : Consequences of degenerative changes].

Welke B, Daentzer D, Neidlinger-Wilke C, Liebsch C Orthopadie (Heidelb). 2024; 53(12):912-917.

PMID: 39499289 DOI: 10.1007/s00132-024-04578-4.


Role of intra-lamellar collagen and hyaluronan nanostructures in annulus fibrosus on lumbar spine biomechanics: insights from molecular mechanics-finite element-based multiscale analyses.

Bhattacharya S, Dubey D Med Biol Eng Comput. 2024; 63(1):139-157.

PMID: 39183226 DOI: 10.1007/s11517-024-03184-y.


Dataset of Finite Element Models of Normal and Deformed Thoracolumbar Spine.

Rasouligandomani M, Del Arco A, Chemorion F, Bisotti M, Galbusera F, Noailly J Sci Data. 2024; 11(1):549.

PMID: 38811573 PMC: 11137096. DOI: 10.1038/s41597-024-03351-8.


Nucleus pulposus structure and function assessed in shear using magnetic resonance elastography, quantitative MRI, and rheometry.

Co M, Raterman B, Klamer B, Kolipaka A, Walter B JOR Spine. 2024; 7(2):e1335.

PMID: 38741919 PMC: 11089841. DOI: 10.1002/jsp2.1335.