Pulmonary Venous Flow Velocities Recorded by Transthoracic Doppler Ultrasound: Relation to Left Ventricular Diastolic Pressures

Overview
Date 1993 Jun 1
PMID 8496538
Citations 46
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: This study was conducted to investigate whether pulmonary venous flow variables measured by transthoracic Doppler ultrasound can help identify patients with elevated left ventricular end-diastolic or filling pressures, or both.

Background: A widened left atrial pressure A wave occurs when left ventricular end-diastolic pressure is increased. Increased duration of pulmonary venous flow reversal at atrial systole might therefore be a marker for elevated end-diastolic pressure. Decreased systolic pulmonary venous flow is shown to be related to increased left ventricular filling pressure in studies using transesophageal Doppler echocardiography.

Methods: Left ventricular pressures at late diastole were measured by fluid-filled catheters in 50 consecutive patients undergoing diagnostic cardiac catheterization. Pulmonary venous and mitral flow velocities were recorded by transthoracic pulsed Doppler ultrasound.

Results: Adequate recordings were obtained in 45 patients. Pulmonary venous flow reversal exceeding the duration of the mitral A wave predicted left ventricular end-diastolic pressure > 15 mm Hg with a sensitivity of 0.85 and a specificity of 0.79. This difference in flow duration correlated well with the increase in ventricular pressure (r = 0.70, p < 0.001) at atrial systole and the end-diastolic pressure (r = 0.68, p < 0.001). The systolic fraction of pulmonary venous flow was markedly decreased (< 0.4) in all patients with a pre-A pressure (left ventricular pressure before atrial systole) > 18 mm Hg.

Conclusions: Pulmonary venous flow reversal exceeding the duration of the mitral A wave indicates an exaggerated increase in left ventricular late diastolic pressure. Pulmonary venous systolic fraction < 0.4 suggests markedly increased ventricular filling pressure.

Citing Articles

The assessment of left ventricular diastolic function: guidance and recommendations from the British Society of Echocardiography.

Robinson S, Ring L, Oxborough D, Harkness A, Bennett S, Rana B Echo Res Pract. 2024; 11(1):16.

PMID: 38825710 PMC: 11145885. DOI: 10.1186/s44156-024-00051-2.


Predictors of Exercise Capacity in Dilated Cardiomyopathy with Focus on Pulmonary Venous Flow Recorded with Transesophageal Eco-Doppler.

Caiati C, Argentiero A, Forleo C, Favale S, Lepera M J Clin Med. 2021; 10(24).

PMID: 34945249 PMC: 8706207. DOI: 10.3390/jcm10245954.


The role of sacubitril/valsartan in the treatment of chronic heart failure with reduced ejection fraction in hypertensive patients with comorbidities: From clinical trials to real-world settings.

Mazza A, Townsend D, Torin G, Schiavon L, Camerotto A, Rigatelli G Biomed Pharmacother. 2021; 130:110596.

PMID: 34321170 PMC: 8963534. DOI: 10.1016/j.biopha.2020.110596.


Pulmonary Congestion Due to Right and Left Heart Output Mismatching: A Case Report and Literature Review.

Yuan J, Li Y, Sun J Front Physiol. 2021; 12:665483.

PMID: 33927647 PMC: 8076790. DOI: 10.3389/fphys.2021.665483.


A Survey on Distributed Fibre Optic Sensor Data Modelling Techniques and Machine Learning Algorithms for Multiphase Fluid Flow Estimation.

Arief H, Wiktorski T, Thomas P Sensors (Basel). 2021; 21(8).

PMID: 33921160 PMC: 8071578. DOI: 10.3390/s21082801.