Artifacts in Intravascular Ultrasound Imaging: Analyses and Implications

Overview
Specialty Radiology
Date 1993 Jan 1
PMID 8310550
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The ability of an intravascular ultrasound catheter to give cross-sectional images of vessel walls and surrounding tissues, and the behavior of ultrasound in heterogeneous media, are at the origin of degradation of image quality. Qualitative and quantitative analyses of in vivo studies are then operator-dependent and are limited by artifacts. We investigated these limitations by an in vitro study on plexiglass phantoms and segments of fresh arteries. We used a 20 MHz transducer mounted on the tip of a 4.8 F catheter and an interventional ultrasound system. The ultrasound beam is reflected onto the rotating transducer at 600 rotations per minute (RPM), creating 360 degrees real-time images (10 images/second). We then observed, analyzed and interpreted the most specific reasons for image artifacts: geometric distortions, multiple echoes, the point spread function (PSF) of the imaging system, near-field effects, "petal-shaped" effect, and ultrasound speckle. Various practical implications have resulted from this study. Only a thorough knowledge of how to avoid some of the most obvious pitfalls will enable the user to obtain maximum benefits from intravascular ultrasound imaging, and to appreciate its limitations.

Citing Articles

The role of noninvasive and invasive diagnostic imaging techniques for detection of extra-cranial venous system anomalies and developmental variants.

Dolic K, Siddiqui A, Karmon Y, Marr K, Zivadinov R BMC Med. 2013; 11:155.

PMID: 23806142 PMC: 3699429. DOI: 10.1186/1741-7015-11-155.


Intravascular ultrasound: principles and cerebrovascular applications.

Zacharatos H, Hassan A, Qureshi A AJNR Am J Neuroradiol. 2010; 31(4):586-97.

PMID: 20133387 PMC: 7964240. DOI: 10.3174/ajnr.A1810.


Mechanism of lumen enlargement with direct stenting versus predilatation stenting: influence of remodelling and plaque characteristics assessed by volumetric intracoronary ultrasound.

Finet G, Weissman N, Mintz G, Satler L, Kent K, Laird J Heart. 2002; 89(1):84-90.

PMID: 12482801 PMC: 1767502. DOI: 10.1136/heart.89.1.84.


Assessing atherosclerotic plaque morphology: comparison of optical coherence tomography and high frequency intravascular ultrasound.

Brezinski M, Tearney G, Weissman N, Boppart S, Bouma B, Hee M Heart. 1997; 77(5):397-403.

PMID: 9196405 PMC: 484757. DOI: 10.1136/hrt.77.5.397.


Parameters that influence accuracy and precision of quantitative coronary arteriography.

Finet G, Lienard J Int J Card Imaging. 1996; 12(4):271-87.

PMID: 8993990 DOI: 10.1007/BF01797741.