Use of Commercial Particle Agglutination Systems for the Rapid Identification of Methicillin-susceptible and Methicillin-resistant Staphylococcus Aureus
Overview
Microbiology
Affiliations
The performance of a recently introduced Staphylococcus aureus identification system (Slidex Staph-Kit) was compared with that of currently available systems (Immuno Scan Staphlatex, Staphyloslide, Staphaurex and SeroSTAT II) for the identification of methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-susceptible Staphylococcus aureus. The new system, which detects a capsular antigen common in MRSA, performed with equal or greater sensitivity than the other systems. None of the commercial systems was adversely affected by the methicillin susceptibility of the staphylococci when isolates were recovered from non-selective media. The greatest advantage of the anti-capsular monoclonal reagent was its improved performance on isolates recovered from selective media.
Rapid detection of epidemic strains of methicillin-resistant Staphylococcus aureus.
Wichelhaus T, Kern S, Schafer V, Brade V J Clin Microbiol. 1999; 37(3):690-3.
PMID: 9986833 PMC: 84522. DOI: 10.1128/JCM.37.3.690-693.1999.
Personne P, Bes M, Lina G, Vandenesch F, Brun Y, Etienne J J Clin Microbiol. 1997; 35(5):1138-40.
PMID: 9114395 PMC: 232717. DOI: 10.1128/jcm.35.5.1138-1140.1997.
Methicillin-resistant Staphylococcus aureus: a continuing infection control challenge.
Boyce J Eur J Clin Microbiol Infect Dis. 1994; 13(1):45-9.
PMID: 8168563 DOI: 10.1007/BF02026126.
Tveten Y J Clin Microbiol. 1995; 33(5):1333-4.
PMID: 7615750 PMC: 228156. DOI: 10.1128/jcm.33.5.1333-1334.1995.