» Articles » PMID: 7968443

High Frequency Volume Coils for Clinical NMR Imaging and Spectroscopy

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 1994 Aug 1
PMID 7968443
Citations 83
Authors
Affiliations
Soon will be listed here.
Abstract

A tuned transmission line resonator has been developed in theory and in practical design for the clinical NMR volume coil application at 4.1 tesla. The distributed circuit transmission line resonator was designed for high frequency, large conductive volume applications where conventional lumped element coil designs perform less efficiently. The resonator design has made use of a resonant coaxial cavity, which could be variably tuned to the Larmor frequency of interest by tunable transmission line elements. Large head- and body-sized volumes, high efficiencies, and broad tuning ranges have been shown to be characteristic of the transmission line resonator to frequencies of 500 MHz. The B1 homogeneity of the resonator has been demonstrated to be a function of the electromagnetic properties of the load itself. By numerically solving Maxwell's equations for the fully time-dependent B1 field, coil homogeneity was predicted with finite-element models of anatomic structure, and inhomogeneities corrected for. A how-to exposition of coil design and construction has been included. Simple methods of quadrature driving and double tuning the transmission line resonator have also been presented. Human head images obtained with a tuned transmission line resonator at 175 MHz have clearly demonstrated uncompromised high field advantages of signal-to-noise and spatial resolution.

Citing Articles

An 8Tx/32Rx head-neck coil at 7T by combining 2Tx/32Rx Nova coil with 6Tx shielded coaxial cable elements.

Guler S, Povaz An M, Zhurbenko V, Zivkovic I Magn Reson Med. 2024; 93(2):864-872.

PMID: 39415491 PMC: 11604854. DOI: 10.1002/mrm.30297.


Subwavelength dielectric waveguide for efficient travelling-wave magnetic resonance imaging.

Gao Y, Liu T, Hong T, Fang Y, Jiang W, Zhang X Nat Commun. 2024; 15(1):2298.

PMID: 38485742 PMC: 10940709. DOI: 10.1038/s41467-024-46638-5.


Double cross magnetic wall decoupling for quadrature transceiver RF array coils using common-mode differential-mode resonators.

Payne K, Bhosale A, Zhang X J Magn Reson. 2023; 353:107498.

PMID: 37295282 PMC: 10527004. DOI: 10.1016/j.jmr.2023.107498.


Design and realization of a multi-coil array for B field control in a compact 1.5T head-only MRI scanner.

Theilenberg S, Shang Y, Ghazouani J, Kumaragamage C, Nixon T, McIntyre S Magn Reson Med. 2023; 90(3):1228-1241.

PMID: 37145035 PMC: 10330274. DOI: 10.1002/mrm.29692.


Hairpin RF resonators for MR imaging transceiver arrays with high inter-channel isolation and B efficiency at ultrahigh field 7 T.

Payne K, Ying L, Zhang X J Magn Reson. 2022; 345:107321.

PMID: 36335877 PMC: 10289884. DOI: 10.1016/j.jmr.2022.107321.