» Articles » PMID: 7858016

A Comparison of Conventional Screen-film Radiography and Hard Copy of Computed Radiography in Full and Two-thirds Sizes in Detection of Interstitial Lung Disease

Overview
Journal J Digit Imaging
Publisher Springer
Date 1994 Nov 1
PMID 7858016
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

This study examined whether hard-copy radiographs produced from computed radiography (CR) images show the subtle interstitial pulmonary disease equally well to conventional screen-film radiographs, because a digital radiography should be chosen for introduction of the digital picture archiving and communication system (PACS) for the new Osaka University Hospital. Eleven radiologists examined 20 abnormal and 20 control chest radiographs presented in each of three groups: conventional screen-film radiographs and two sizes of hard-copy radiographs made from CR images. This study of digital image quality of chest examinations found that some findings on conventional screen-film radiography images are not reproduced by current CR (2,000 x 2,000 x 10 bits in matrix), especially when the experienced radiologists were observed. This finding suggested improvements are needed in CR before CR of chest should fully replace conventional screen-film radiography.

Citing Articles

Does products liability litigation threaten picture archiving and communication systems and/or telemedicine?.

McMenamin J J Digit Imaging. 1998; 11(1):21-32.

PMID: 9502323 PMC: 3453148. DOI: 10.1007/BF03168722.


The value of current developments in radiology to the accident and emergency department--a pictorial review.

Lloyd D J Accid Emerg Med. 1997; 14(6):381-6.

PMID: 9413779 PMC: 1342980. DOI: 10.1136/emj.14.6.381.


Detection of interstitial lung abnormalities on picture archive and communication system video monitors.

Washowich T, Williams S, Richardson L, Simmons G, Dao N, Allen T J Digit Imaging. 1997; 10(1):34-9.

PMID: 9147526 PMC: 3453189. DOI: 10.1007/BF03168548.


Time and flow study results before and after installation of a hospital information system and radiology information system and before clinical use of a picture archiving and communication system.

Inamura K, Umeda T, Harauchi H, Kondoh H, Hasegawa T, Kozuka T J Digit Imaging. 1997; 10(1):1-9.

PMID: 9147521 PMC: 3453186. DOI: 10.1007/BF03168543.


Initial data-element selection for the evaluation of picture archiving and communication system performance.

Kondoh H, Ikezoe J, Inamura K, Kuroda C, Kozuka T J Digit Imaging. 1994; 7(4):177-82.

PMID: 7858013 DOI: 10.1007/BF03168536.

References
1.
Kuroda C, Kondoh H, Takeda H, Inoue M, Inamura K, Mori Y . Planning for PACS at Osaka University Hospital. Comput Methods Programs Biomed. 1991; 36(2-3):147-50. DOI: 10.1016/0169-2607(91)90064-z. View

2.
Sanada S, Doi K, Xu X, Yin F, Giger M, Macmahon H . Comparison of imaging properties of a computed radiography system and screen-film systems. Med Phys. 1991; 18(3):414-20. DOI: 10.1118/1.596688. View

3.
Macmahon H, Vyborny C, Metz C, Doi K, Sabeti V, Solomon S . Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance. Radiology. 1986; 158(1):21-6. DOI: 10.1148/radiology.158.1.3940383. View