» Articles » PMID: 7772665

In Vivo Degradation and Biocompatibility Study of in Vitro Pre-degraded As-polymerized Polyactide Particles

Overview
Journal Biomaterials
Date 1995 Mar 1
PMID 7772665
Citations 38
Authors
Affiliations
Soon will be listed here.
Abstract

The degradation of high molecular weight as-polymerized poly(L-lactide) (PLLA) is very slow; it takes more than 5.6 yr for total resorption. Moreover, the degradation products of as-polymerized PLLA bone plates, consisting of numerous stable particles of high crystallinity, are related with a subcutaneous swelling in patients 3 yr postoperatively. In order to avoid these complications, polymers were developed that are anticipated to have comparable mechanical properties but a higher degradation rate and do not degrade into highly stable particles that can induce a subcutaneous swelling. On chemical grounds it can be expected that copolymerization of PLLA with 4% D-lactide (PLA96) or by modifying PLLA through cross-linking (CL-PLLA) will lead to less stable particles and a higher degradation rate. To evaluate the long-term suitability of these as-polymerized polymers, the biocompatibility of the degradation products should be studied. Considering the very slow degradation rate of as-polymerized PLLA, in vitro pre-degradation at elevated temperatures was used to shorten the in vivo follow-up periods. In this study, the biocompatibility and degradation of as-polymerized PLLA, PLA96 and CL-PLLA were investigated by implanting pre-degraded particulate materials subcutaneously in rats. Animals were killed after a postoperative period varying from 3 to 80 wk. Light and electron microscopical analysis and quantitative measurements were performed. The histological response of all three pre-degraded materials showed a good similarity with in vivo implanted material. Pre-degraded PLLA induced a mild foreign body reaction and showed a slow degradation rate.(ABSTRACT TRUNCATED AT 250 WORDS)

Citing Articles

Bone Incorporation of a Poly (L-Lactide-Co-D, L-Lactide) Internal Fixation Device in a Rat's Tibia: Microtomographic, Confocal LASER, and Histomorphometric Analysis.

Mamani-Valeriano H, Silva N, Nimia H, Pereira-Silva M, Oliveira M, Rodrigues L Biology (Basel). 2024; 13(7).

PMID: 39056666 PMC: 11273520. DOI: 10.3390/biology13070471.


Sutureless vascular anastomotic approaches and their potential impacts.

Ribaudo J, He K, Madira S, Young E, Martin C, Lu T Bioact Mater. 2024; 38:73-94.

PMID: 38699240 PMC: 11061647. DOI: 10.1016/j.bioactmat.2024.04.003.


The Potential for Foreign Body Reaction of Implanted Poly-L-Lactic Acid: A Systematic Review.

Nonhoff M, Puetzler J, Hasselmann J, Fobker M, Gosheger G, Schulze M Polymers (Basel). 2024; 16(6).

PMID: 38543422 PMC: 10974195. DOI: 10.3390/polym16060817.


Characterization of Acellular Cartilage Matrix-Sodium Alginate Scaffolds in Various Proportions.

Lu W, Yang M, Zhang Y, Meng B, Ma F, Wang W Tissue Eng Part C Methods. 2024; 30(4):170-182.

PMID: 38420649 PMC: 11001505. DOI: 10.1089/ten.TEC.2023.0348.


Biomaterials in Traumatic Brain Injury: Perspectives and Challenges.

Aqel S, Al-Thani N, Haider M, Abdelhady S, Al Thani A, Kobeissy F Biology (Basel). 2024; 13(1).