» Articles » PMID: 7731155

Nephrotoxicity of Ionic and Nonionic Contrast Media in 1196 Patients: a Randomized Trial. The Iohexol Cooperative Study

Overview
Journal Kidney Int
Publisher Elsevier
Specialty Nephrology
Date 1995 Jan 1
PMID 7731155
Citations 142
Authors
Affiliations
Soon will be listed here.
Abstract

The incidence of nephrotoxicity occurring with the nonionic contrast agent, iohexol, and the ionic contrast agent, meglumine/sodium diatrizoate, was compared in 1196 patients undergoing cardiac angiography in a prospective, randomized, double-blind multicenter trial. Patients were stratified into four groups: renal insufficiency (RI), diabetes mellitus (DM) both absent (N = 364); RI absent, DM present (N = 318); RI present, DM absent (N = 298); and RI and DM both present (N = 216). Serum creatinine levels were measured at -18 to 24, 0, and 24, 48, and 72 hours following contrast administration. Prophylactic hydration was administered pre- and post-angiography. Acute nephrotoxicity (increase in serum creatinine of > or = 1 mg/dl 48 to 72 hours post-contrast) was observed in 42 (7%) patients receiving diatrizoate compared to 19 (3%) patients receiving iohexol, P < 0.002. Differences in nephrotoxicity between the two contrast groups were confined to patients with RI alone or combined with DM. In a multivariate analysis, baseline serum creatinine, male gender, DM, volume of contrast agent, and RI were independently related to the risk of nephrotoxicity. Patients with RI receiving diatrizoate were 3.3 times as likely to develop acute nephrotoxicity compared to those receiving iohexol. Clinically severe adverse renal events were uncommon (N = 15) and did not differ in incidence between contrast groups (iohexol N = 6; diatrizoate N = 9). In conclusion, in patients undergoing cardiac angiography, only those with pre-existing RI alone or combined with DM are at higher risk for acute contrast nephrotoxicity.(ABSTRACT TRUNCATED AT 250 WORDS)

Citing Articles

Post-contrast acute kidney injury in the super-elder patients: a CT-scan perspective.

Fraenkel Y, Bogot N, Kuint R, Ben-Shalom E, Benjaminov O, Bnaya A Jpn J Radiol. 2024; 43(2):247-254.

PMID: 39264543 DOI: 10.1007/s11604-024-01656-7.


Diagnostic Algorithm for Intracranial Lesions in the Emergency Department: Effectiveness of the Relative Brain Volume and Hounsfield Unit Value Measured by Perfusion Tomography.

Alvaro-Heredia J, Rodriguez-Hernandez L, Rodriguez-Rubio H, Alvaro-Heredia I, Mondragon-Soto M, Rodriguez-Hernandez I Cureus. 2024; 16(6):e61591.

PMID: 38962639 PMC: 11221499. DOI: 10.7759/cureus.61591.


Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement.

Chang S, Jung J, Beck K, Chang K, Kim Y, Han K Korean J Radiol. 2024; 25(7):634-643.

PMID: 38942457 PMC: 11214918. DOI: 10.3348/kjr.2023.1207.


Autonomous navigation of catheters and guidewires in mechanical thrombectomy using inverse reinforcement learning.

Robertshaw H, Karstensen L, Jackson B, Granados A, Booth T Int J Comput Assist Radiol Surg. 2024; 19(8):1569-1578.

PMID: 38884893 PMC: 7616368. DOI: 10.1007/s11548-024-03208-w.


Patient characteristics associated with acute kidney injury following coronary angiography.

Knott J, Engheta M, Michel J, Mixon T, Widmer R Proc (Bayl Univ Med Cent). 2024; 37(3):382-387.