» Articles » PMID: 7576395

White Coat Hypertension and White Coat Effect. Similarities and Differences

Overview
Journal Am J Hypertens
Date 1995 Aug 1
PMID 7576395
Citations 34
Authors
Affiliations
Soon will be listed here.
Abstract

The rise in blood pressure (BP) associated with clinical visit (white coat effect) may be one basic mechanism of white coat hypertension (persistently raised clinic BP together with a normal BP outside the clinic), but the relations between white coat hypertension, white coat effect, and target organ damage have not yet been assessed on large populations. Thus, we performed 24-h noninvasive ambulatory BP monitoring and 2D-guided M-mode echocardiography in 1,333 untreated subjects with essential hypertension and 178 control normotensive subjects. White coat hypertension was defined by an average daytime ambulatory BP < 131/86 mm Hg in women and < 136/87 mm Hg in men and its prevalence was 18.9% (n = 252). The white coat effect was calculated for systolic and diastolic BP as the difference between clinic BP and average daytime ambulatory BP. Echocardiographic left ventricular mass was slightly but not significantly greater in the group with white coat hypertension than in the normotensive group (93 v 87 g/m2, P = NS), and increased in the group with ambulatory hypertension (112 g/m2, P < .01). The prevalence of white coat hypertension markedly decreased from the first to the fourth Joint National Committee V (JNC V) stage of severity of hypertension (186/559 subjects (33%) in I; 59/501 (11%) in II; 7/230 (3%) in III; 0/43 (0%) in IV; P < .001).(ABSTRACT TRUNCATED AT 250 WORDS)

Citing Articles

The association between ozone exposure and blood pressure in a general Chinese middle-aged and older population: a large-scale repeated-measurement study.

Tang C, Zhang Y, Yi J, Lu Z, Xuan X, Jiang H BMC Med. 2024; 22(1):559.

PMID: 39593059 PMC: 11600574. DOI: 10.1186/s12916-024-03783-4.


The Analytical Validity of Stride Detection and Gait Parameters Reconstruction Using the Ankle-Mounted Inertial Measurement Unit Syde.

Michaud M, Guerin A, Dejean de La Batie M, Bancel L, Oudre L, Tricot A Sensors (Basel). 2024; 24(8).

PMID: 38676029 PMC: 11054238. DOI: 10.3390/s24082413.


White Coat Effect: Is It Because of the Hospital Setting, or Is It Physician-Induced?.

Singh M, Singh N, Pahuja H, Arora R, Anshul , Patel H Cureus. 2023; 15(4):e38144.

PMID: 37257162 PMC: 10214880. DOI: 10.7759/cureus.38144.


Personalized hypertension treatment recommendations by a data-driven model.

Hu Y, Huerta J, Cordella N, Mishuris R, Paschalidis I BMC Med Inform Decis Mak. 2023; 23(1):44.

PMID: 36859187 PMC: 9979505. DOI: 10.1186/s12911-023-02137-z.


Unattended compared to traditional blood pressure measurement in patients with rheumatoid arthritis: a randomised cross-over study.

Bartoloni E, Angeli F, Marcucci E, Perricone C, Cafaro G, Riccini C Ann Med. 2021; 53(1):2050-2059.

PMID: 34751628 PMC: 8583925. DOI: 10.1080/07853890.2021.1999493.