Comparison of Impedance Cardiography and Echocardiography for Measurement of Stroke Volume

Overview
Specialty Pharmacology
Date 1982 Jan 1
PMID 7160414
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

The relationship between stroke volume (SV) measured simultaneously by impedance cardiography (SVI) and echocardiography (SVE) has been analyzed. Change in stroke volume in 6 healthy volunteers was induced by passive head-up tilting (80 degrees) and by oral administration of the sympathomimetic drug amezinium. A correlation of r = 0.83 (p much less than 0.01) was found between SVI and SVE calculated by the equation: SVE = 16.0 + (0.528 x SVI). Though stroke volume is overestimated by impedance cardiography, the method may be useful for the clinical pharmacologist interested in a simple non-invasive tool to estimate stroke volume and change in it.

Citing Articles

Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network.

Naidu S, Pandey P, Bagal U, Hardas S Med Biol Eng Comput. 2017; 56(6):1077-1089.

PMID: 29150800 DOI: 10.1007/s11517-017-1752-5.


Stroke volume and systolic time intervals: beat-to-beat comparison between echocardiography and ambulatory impedance cardiography in supine and tilted positions.

Cybulski G, Michalak E, Kozluk E, Piatkowska A, Niewiadomski W Med Biol Eng Comput. 2004; 42(5):707-11.

PMID: 15503973 DOI: 10.1007/BF02347554.


Influence of age on the immediate cardiovascular response to orthostatic manoeuvre.

Cybulski G Eur J Appl Physiol Occup Physiol. 1996; 73(6):563-72.

PMID: 8817128 DOI: 10.1007/BF00357680.


Dose-dependent heart rate reducing effect of nizatidine, a histamine H2-receptor antagonist.

Hinrichsen H, Halabi A, Fuhrmann G, Kirch W Br J Clin Pharmacol. 1993; 35(5):461-6.

PMID: 8099802 PMC: 1381682. DOI: 10.1111/j.1365-2125.1993.tb04170.x.


Pitfalls and limitations in the use of impedance cardiography.

de Mey C, Belz G Br Heart J. 1989; 61(1):128-9.

PMID: 2917094 PMC: 1216625. DOI: 10.1136/hrt.61.1.128.


References
1.
Fortuin N, Hood Jr W, CRAIGE E . Evaluation of left ventricular function by echocardiography. Circulation. 1972; 46(1):26-35. DOI: 10.1161/01.cir.46.1.26. View

2.
Kiowski W, Randall O, Steffens T, Julius S . Reliability of echocardiography in assessing cardiac output. A comparative study with a dye dilution technique. Klin Wochenschr. 1981; 59(19):1115-20. DOI: 10.1007/BF01746199. View

3.
Hill D, Thompson F . The effect of haematocrit on the resistivity of human blood at 37 degrees C and 100 kHz. Med Biol Eng. 1975; 13(2):182-6. DOI: 10.1007/BF02477725. View

4.
Erbel R, Schweizer P . [The diagnostic value of echocardiography in coronary artery disease--1. M-mode echocardiogrpahy (author's transl)]. Z Kardiol. 1980; 69(6):391-7. View

5.
Pombo J, Troy B, Russell Jr R . Left ventricular volumes and ejection fraction by echocardiography. Circulation. 1971; 43(4):480-90. DOI: 10.1161/01.cir.43.4.480. View