» Articles » PMID: 6604139

Brain Blood Flow Measured with Intravenous H2(15)O. I. Theory and Error Analysis

Overview
Journal J Nucl Med
Specialty Nuclear Medicine
Date 1983 Sep 1
PMID 6604139
Citations 177
Authors
Affiliations
Soon will be listed here.
Abstract

The tissue autoradiographic method for the measurement of regional cerebral blood flow (rCBF) in animals was adapted for use with positron emission tomography (PET). Because of the limited spatial resolution of PET, a region of interest will contain a mix of gray and white matter, inhomogeneous in flow and in tracer partition coefficient (lambda). The resultant error in rCBF, however, is less than 4%. Although the tissue autoradiographic method requires a monotonically increasing input function to ensure a unique solution for flow, the PET adaptation does not, because of an additional integration in the operational equation. Simulation showed that the model is accurate in the presence of ischemia or hyperemia of the gray matter. Inaccuracy in timing of the arterial input function will result in large errors in rCBF measurement. Propagation of errors in measurement of tissue activity is largely independent of flow, reflecting the nearly linear flow compared with activity relationship.

Citing Articles

Physiological provocation compared to acetazolamide in the assessment of cerebral hemodynamics: a case report.

Henriksen A, Thomsen G, Knudsen G, Stavngaard T, Rosenbaum S, Marner L EJNMMI Res. 2024; 14(1):89.

PMID: 39356412 PMC: 11447169. DOI: 10.1186/s13550-024-01154-x.


[O]HO PET/MRI for Assessment of Complete Response to Neoadjuvant or Induction Chemotherapy in Patients with Muscle-Invasive Bladder Cancer: A Pilot Study.

Korner S, Tolbod L, Pedersen B, Boellaard T, Milling R, Brandt S J Clin Med. 2024; 13(16).

PMID: 39200797 PMC: 11354727. DOI: 10.3390/jcm13164652.


Validation of the Openwater wearable optical system: cerebral hemodynamic monitoring during a breath-hold maneuver.

Favilla C, Carter S, Hartl B, Gitlevich R, Mullen M, Yodh A Neurophotonics. 2024; 11(1):015008.

PMID: 38464864 PMC: 10923543. DOI: 10.1117/1.NPh.11.1.015008.


Head-to-head comparison of relative cerebral blood flow derived from dynamic [F]florbetapir and [F]flortaucipir PET in subjects with subjective cognitive decline.

Tuncel H, Visser D, Timmers T, Wolters E, Ossenkoppele R, van der Flier W EJNMMI Res. 2023; 13(1):93.

PMID: 37889456 PMC: 10611685. DOI: 10.1186/s13550-023-01041-x.


Measurement of Cerebral Perfusion Indices from the Early Phase of [F]MK6240 Dynamic Tau PET Imaging.

Guehl N, Dhaynaut M, Hanseeuw B, Moon S, Lois C, Thibault E J Nucl Med. 2023; 64(6):968-975.

PMID: 36997330 PMC: 10241011. DOI: 10.2967/jnumed.122.265072.