» Articles » PMID: 6258478

Concentration of Poliovirus in Water by Molecular Filtration

Overview
Date 1980 Aug 1
PMID 6258478
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

The efficiency of concentrating poliovirus 1 from distilled water samples was determined by using a recirculating-flow molecular filtration system. The most efficient recoveries were achieved against members with a 10,000 nominal molecular weight limit pretreated with flocculated beef extract. This procedure yielded a mean virus recovery of 67%.

Citing Articles

An Appraisal of Bacteriophage Isolation Techniques from Environment.

Nair A, Ghugare G, Khairnar K Microb Ecol. 2021; 83(3):519-535.

PMID: 34136953 DOI: 10.1007/s00248-021-01782-z.


Elution Is a Critical Step for Recovering Human Adenovirus 40 from Tap Water and Surface Water by Cross-Flow Ultrafiltration.

Shi H, Xagoraraki I, Parent K, Bruening M, Tarabara V Appl Environ Microbiol. 2016; 82(16):4982-93.

PMID: 27287319 PMC: 4968539. DOI: 10.1128/AEM.00870-16.


Concentration and recovery of viruses from water: a comprehensive review.

Ikner L, Gerba C, Bright K Food Environ Virol. 2013; 4(2):41-67.

PMID: 23412811 DOI: 10.1007/s12560-012-9080-2.


Concentration and detection of cryptosporidium oocysts in surface water samples by method 1622 using ultrafiltration and capsule filtration.

Simmons 3rd O, Sobsey M, Heaney C, Schaefer 3rd F, Francy D Appl Environ Microbiol. 2001; 67(3):1123-7.

PMID: 11229901 PMC: 92704. DOI: 10.1128/AEM.67.3.1123-1127.2001.


Membrane ultrafiltration: concentration of interleukin-3.

Klein F, Ricketts R, Rohrer T, Jones Jr W, Clark P, Flickinger M Appl Environ Microbiol. 1984; 47(5):1023-6.

PMID: 6430227 PMC: 240045. DOI: 10.1128/aem.47.5.1023-1026.1984.


References
1.
Gangemi J, Connell E, MAHLANDT B, Eddy G . Arenavirus concentration by molecular filtration. Appl Environ Microbiol. 1977; 34(3):330-2. PMC: 242652. DOI: 10.1128/aem.34.3.330-332.1977. View

2.
Berg G, Dahling D, Berman D . Recovery of small quantities of viruses from clean waters on cellulose nitrate membrane filters. Appl Microbiol. 1971; 22(4):608-14. PMC: 376372. DOI: 10.1128/am.22.4.608-614.1971. View

3.
Sobsey M, Jones B . Concentration of poliovirus from tap water using positively charged microporous filters. Appl Environ Microbiol. 1979; 37(3):588-95. PMC: 243259. DOI: 10.1128/aem.37.3.588-595.1979. View

4.
Farrah S, Goyal S, Gerba C, Wallis C, Melnick J . Concentration of poliovirus from tap water onto membrane filters with aluminum chloride at ambient pH levels. Appl Environ Microbiol. 1978; 35(3):624-6. PMC: 242890. DOI: 10.1128/aem.35.3.624-626.1978. View

5.
Mathes L, YOHN D, Olsen R . Purification of infectious feline leukemia virus from large volumes of tissue culture fluids. J Clin Microbiol. 1977; 5(3):372-4. PMC: 274600. DOI: 10.1128/jcm.5.3.372-374.1977. View