Singh R, Mishra P, Singh A, Srivastava D, Gupta V, Malviya D
Cureus. 2022; 14(3):e22772.
PMID: 35371837
PMC: 8971127.
DOI: 10.7759/cureus.22772.
Burman S, Sharma P, Tyagi M, Singh G, Chaturvedi A
Indian J Crit Care Med. 2021; 24(12):1281-1283.
PMID: 33446988
PMC: 7775932.
DOI: 10.5005/jp-journals-10071-23686.
Tusman G, Campos M, Gogniat E
Rev Esp Anestesiol Reanim (Engl Ed). 2020; 67(7):367-373.
PMID: 32419705
PMC: 7225690.
DOI: 10.1016/j.redar.2020.05.002.
Fukunaga A
J Anesth. 2019; 33(2):317-320.
PMID: 30859365
PMC: 6443618.
DOI: 10.1007/s00540-019-02622-8.
Mizrak A, Bilgi M, Koruk S, Ganidagli S, Karatas E, Oner U
Eurasian J Med. 2015; 43(2):92-8.
PMID: 25610171
PMC: 4261343.
DOI: 10.5152/eajm.2011.21.
Mapleson's Breathing Systems.
Kaul T, Mittal G
Indian J Anaesth. 2013; 57(5):507-15.
PMID: 24249884
PMC: 3821268.
DOI: 10.4103/0019-5049.120148.
Hypercapnia resulting from a faulty co-axial (Bain) circuit.
Singh I, Gupta M, Singh T
Indian J Anaesth. 2011; 55(4):402-4.
PMID: 22013262
PMC: 3190520.
DOI: 10.4103/0019-5049.84853.
A mass balance model for the Mapleson D anaesthesia breathing system.
Lovich M, Simon B, Venegas J, Sims N, Cooper J
Can J Anaesth. 1993; 40(6):554-67.
PMID: 8403123
DOI: 10.1007/BF03009741.
Bain circuit occluded by foreign body.
Wilkes P, Lindsay P
Can J Anaesth. 1994; 41(2):137-9.
PMID: 8131228
DOI: 10.1007/BF03009807.
Cimetidine and prolonged post-operative somnolence.
Lam A, Parkin J
Can Anaesth Soc J. 1981; 28(5):450-2.
PMID: 7284887
DOI: 10.1007/BF03010354.
PEEP and the Bain circuit.
Arandia H, BYLES P
Can Anaesth Soc J. 1981; 28(5):467-70.
PMID: 7025997
DOI: 10.1007/BF03010358.
Resistance to gas flow in the "new" anaesthesia circuits: a comparative study.
Shandro J
Can Anaesth Soc J. 1982; 29(4):387-90.
PMID: 6809297
DOI: 10.1007/BF03007532.
The Lack, Magill and Bain anaesthetic breathing systems: a direct comparison in spontaneously-breathing anaesthetized adults.
Humphrey D
J R Soc Med. 1982; 75(7):513-24.
PMID: 6806473
PMC: 1437895.
DOI: 10.1177/014107688207500706.
Arterial to end-tidal carbon dioxide tension difference in children under halothane anaesthesia.
Valentin N, Lomholt B, Thorup M
Can Anaesth Soc J. 1982; 29(1):12-5.
PMID: 6799179
DOI: 10.1007/BF03007941.
High dose fentanyl anaesthesia with oxygen for aorto-coronary bypass surgery.
Quintin L, Whalley D, Wynands J, MORIN J, Burke J
Can Anaesth Soc J. 1981; 28(4):314-20.
PMID: 6790139
DOI: 10.1007/BF03007796.
Rebreathing and carbon dioxide elimination with the Bain circuit.
Spoerel W
Can Anaesth Soc J. 1980; 27(4):357-62.
PMID: 6773638
DOI: 10.1007/BF03007457.
Safety check for the Bain circuit.
Ghani G
Can Anaesth Soc J. 1984; 31(4):487-8.
PMID: 6744096
DOI: 10.1007/BF03015432.
Rebreathing and end-tidal CO2 during spontaneous breathing with the Bain circuit.
Spoerel W
Can Anaesth Soc J. 1983; 30(2):148-54.
PMID: 6403205
DOI: 10.1007/BF03009344.
A redesigned anaesthetic gas machine.
Spoerel W, Bain J, Heinrich G
Can Anaesth Soc J. 1974; 21(3):335-42.
PMID: 4838331
DOI: 10.1007/BF03005739.
Flow requirements for a modified Mapleson D system during controlled ventilation.
Bain J, Spoerel W
Can Anaesth Soc J. 1973; 20(5):629-36.
PMID: 4521733
DOI: 10.1007/BF03026260.