» Articles » PMID: 39797045

Recent Advancements in Localization Technologies for Wireless Capsule Endoscopy: A Technical Review

Overview
Journal Sensors (Basel)
Publisher MDPI
Date 2025 Jan 11
PMID 39797045
Authors
Affiliations
Soon will be listed here.
Abstract

Conventional endoscopy is limited in its ability to examine the small bowel and perform long-term monitoring due to the risk of infection and tissue perforation. Wireless Capsule Endoscopy (WCE) is a painless and non-invasive method of examining the body's internal organs using a small camera that is swallowed like a pill. The existing active locomotion technologies do not have a practical localization system to control the capsule's movement within the body. A robust localization system is essential for safely guiding the WCE device through the complex gastrointestinal (GI) tract. Moreover, having access to the capsule's trajectory data is highly desirable for drug delivery and surgery, as well as for creating accurate user profiles for diagnosis and future reference. Therefore, a robust, real-time, and practical localization system is imperative to advance the field of WCE and make it desirable for clinical trials. In this work, we have identified salient features of different localization techniques and categorized studies in comprehensive tables. This study is self-contained as it offers a comprehensive overview of emerging localization techniques based on magnetic field, radio frequency (RF), video, and hybrid methods. A summary at the end of each method is provided to point out the potential gaps and give directions for future research. The main point of this work is to present an in-depth review of the most recent localization techniques published in the past five years. This will assist researchers in comprehending current techniques and pinpointing potential areas for further investigation. This review can be a significant reference and guide for future research on WCE localization.

References
1.
Arefin M, Redoute J, Yuce M . Integration of Low-Power ASIC and MEMS Sensors for Monitoring Gastrointestinal Tract Using a Wireless Capsule System. IEEE J Biomed Health Inform. 2017; 22(1):87-97. DOI: 10.1109/JBHI.2017.2690965. View

2.
Sun Y, Zhang W, Gu J, Xia L, Cao Y, Zhu X . Magnetically driven capsules with multimodal response and multifunctionality for biomedical applications. Nat Commun. 2024; 15(1):1839. PMC: 10904804. DOI: 10.1038/s41467-024-46046-9. View

3.
Hany U, Akter L . Accuracy of UWB Path Loss-Based Localization of Wireless Capsule Endoscopy. J Healthc Eng. 2023; 2023:3156013. PMC: 10281820. DOI: 10.1155/2023/3156013. View

4.
Yao L, Khan S, Dolmans G, Romme J, Mitra S . High Accuracy Localization for Miniature Ingestible Devices Using Mutual Inductance. IEEE Trans Biomed Circuits Syst. 2024; 18(3):662-678. DOI: 10.1109/TBCAS.2024.3361045. View

5.
Vats A, Pedersen M, Mohammed A, Hovde O . Evaluating clinical diversity and plausibility of synthetic capsule endoscopic images. Sci Rep. 2023; 13(1):10857. PMC: 10322862. DOI: 10.1038/s41598-023-36883-x. View