» Articles » PMID: 35741143

Tracking the Traveled Distance of Capsule Endoscopes Along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization

Overview
Specialty Radiology
Date 2022 Jun 24
PMID 35741143
Authors
Affiliations
Soon will be listed here.
Abstract

The traveled distance and orientation of capsule endoscopes for each video frame are not available in commercial systems, but they would be highly relevant for physicians. Furthermore, scientific approaches lack precisely tracking the capsules along curved trajectories within the typical gastrointestinal tract. Recently, we showed that the differential static magnetic localisation method is suitable for the precise absolute localisation of permanent magnets assumed to be integrated into capsule endoscopes. Thus, in the present study, the differential method was employed to track permanent magnets in terms of traveled distance and orientation along a length trajectory of 487.5 mm, representing a model of the winding gastrointestinal tract. Permanent magnets with a diameter of 10 mm and different lengths were used to find a lower boundary for magnet size. Results reveal that the mean relative distance and orientation errors did not exceed 4.3 ± 3.3%, and 2 ± 0.6∘, respectively, when the magnet length was at least 5 mm. Thus, a 5 mm long magnet would be a good compromise between achievable tracking accuracy and magnet volume, which are essential for integration into small commercial capsules. Overall, the proposed tracking accuracy was better than that of the state of the art within a region covering the typical gastrointestinal-tract size.

Citing Articles

Recent Advancements in Localization Technologies for Wireless Capsule Endoscopy: A Technical Review.

Ali M, Tom N, Alsunaydih F, Yuce M Sensors (Basel). 2025; 25(1.

PMID: 39797045 PMC: 11723480. DOI: 10.3390/s25010253.


Endoscopic capsule robot-based diagnosis, navigation and localization in the gastrointestinal tract.

Hanscom M, Cave D Front Robot AI. 2022; 9:896028.

PMID: 36119725 PMC: 9479458. DOI: 10.3389/frobt.2022.896028.

References
1.
Zeising S, Ararat K, Thalmayer A, Anzai D, Fischer G, Kirchner J . Systematic Performance Evaluation of a Novel Optimized Differential Localization Method for Capsule Endoscopes. Sensors (Basel). 2021; 21(9). PMC: 8125465. DOI: 10.3390/s21093180. View

2.
Marya N, Karellas A, Foley A, Roychowdhury A, Cave D . Computerized 3-dimensional localization of a video capsule in the abdominal cavity: validation by digital radiography. Gastrointest Endosc. 2014; 79(4):669-74. DOI: 10.1016/j.gie.2013.11.022. View

3.
Flemming J, Cameron S . Small bowel capsule endoscopy: Indications, results, and clinical benefit in a University environment. Medicine (Baltimore). 2018; 97(14):e0148. PMC: 5902276. DOI: 10.1097/MD.0000000000010148. View

4.
Bianchi F, Masaracchia A, Barjuei E, Menciassi A, Arezzo A, Koulaouzidis A . Localization strategies for robotic endoscopic capsules: a review. Expert Rev Med Devices. 2019; 16(5):381-403. DOI: 10.1080/17434440.2019.1608182. View

5.
Dimas G, Spyrou E, Iakovidis D, Koulaouzidis A . Intelligent visual localization of wireless capsule endoscopes enhanced by color information. Comput Biol Med. 2017; 89:429-440. DOI: 10.1016/j.compbiomed.2017.08.029. View