» Articles » PMID: 39764373

Morphologic Study of Patent Ductus Arteriosus Based on Computed Tomography Data in 25 Dogs

Abstract

Introduction: The objective of this study is to analyze the morphology and measurement dimensions of patent ductus arteriosus (PDA) based on computed tomography images.

Methods: The present study retrospectively evaluated computed tomography angiography data from 25 client-owned dogs diagnosed with PDA. PDA was reconstructed based on the central axis and the minimum diameter, ampulla diameter, angle, ampulla cross-section area, and length values were measured at specific measurement sites. Additionally, the minimum diameter ratio, ampulla diameter ratio, ampulla cross-section diameter, and ampulla cross-section diameter/ampulla diameter ratio values were calculated based on direct measurement values.

Results And Discussion: The morphology of PDA was distributed as follows: 48% Type IIA, 20% Type IIB, and 32% Type III. A significant correlation was observed between the minimal diameter sagittal and transverse and the ampulla diameter sagittal and transverse, body weight, and angle (descending aorta to PDA). A significant association was observed between ampulla diameter (in both the sagittal and transverse planes) and body weight. The minimal diameter ratio did not demonstrate a significant correlation with the ampulla diameter, body weight, angle and length. However, the ampulla diameter ratio exhibited a significant correlation with the length of the PDA and the angle (descending aorta to PDA). The minimal diameter ratio displayed results that were more closely approximated by a circle, whereas the ampulla diameter ratio showed results that were relatively oval. The ampulla cross-section diameter values differed by an average of 14% from the previously used reference length, ampulla diameter sagittal.

Conclusion: The computed tomography image demonstrated the distinctive cross-sectional configuration of the PDA, which could potentially facilitate advanced pre-procedural planning or the creation of novel occluding devices in the future.

References
1.
Achen S, Miller M, Gordon S, Saunders A, Roland R, Drourr L . Transarterial ductal occlusion with the Amplatzer vascular plug in 31 dogs. J Vet Intern Med. 2008; 22(6):1348-52. DOI: 10.1111/j.1939-1676.2008.0185.x. View

2.
Saunders A, Gordon S, Boggess M, Miller M . Long-term outcome in dogs with patent ductus arteriosus: 520 cases (1994-2009). J Vet Intern Med. 2013; 28(2):401-10. PMC: 4857963. DOI: 10.1111/jvim.12267. View

3.
Barratt D, Ariff B, Humphries K, Thom S, Hughes A . Reconstruction and quantification of the carotid artery bifurcation from 3-D ultrasound images. IEEE Trans Med Imaging. 2004; 23(5):567-83. DOI: 10.1109/tmi.2004.825601. View

4.
Gordon S, Saunders A, Achen S, Roland R, Drourr L, Hariu C . Transarterial ductal occlusion using the Amplatz Canine Duct Occluder in 40 dogs. J Vet Cardiol. 2010; 12(2):85-92. DOI: 10.1016/j.jvc.2010.04.004. View

5.
Nguyenba T, Tobias A . Minimally invasive per-catheter patent ductus arteriosus occlusion in dogs using a prototype duct occluder. J Vet Intern Med. 2008; 22(1):129-34. DOI: 10.1111/j.1939-1676.2007.0009.x. View