» Articles » PMID: 39720013

Obtaining Super-resolved Images at the Mesoscale Through Super-resolution Radial Fluctuations

Overview
Journal J Biomed Opt
Date 2024 Dec 25
PMID 39720013
Authors
Affiliations
Soon will be listed here.
Abstract

Significance: Current super-resolution imaging techniques allow for a greater understanding of cellular structures; however, they are often complex or only have the ability to image a few cells at once. This small field of view (FOV) may not represent the behavior across the entire sample, and manual selection of regions of interest (ROIs) may introduce bias. It is possible to stitch and tile many small ROIs; however, this can result in artifacts across an image.

Aim: The aim is to achieve accurate super-resolved images across a large FOV ( ).

Approach: We have applied super-resolution radial fluctuations processing in conjunction with the Mesolens, which has the unusual combination of a low-magnification and high numerical aperture, to obtain super-resolved images.

Results: We demonstrate it is possible to achieve images with a resolution of , providing a -fold improvement in spatial resolution, over an FOV of , with minimal error, and consistent structural agreement.

Conclusions: We provide a simple method for obtaining accurate super-resolution images over a large FOV, allowing for a simultaneous understanding of both subcellular structures and their large-scale interactions.

References
1.
Ortkrass H, Schurstedt J, Wiebusch G, Szafranska K, McCourt P, Huser T . High-speed TIRF and 2D super-resolution structured illumination microscopy with a large field of view based on fiber optic components. Opt Express. 2023; 31(18):29156-29165. DOI: 10.1364/OE.495353. View

2.
Preibisch S, Saalfeld S, Tomancak P . Globally optimal stitching of tiled 3D microscopic image acquisitions. Bioinformatics. 2009; 25(11):1463-5. PMC: 2682522. DOI: 10.1093/bioinformatics/btp184. View

3.
Hell S, Wichmann J . Breaking the diffraction resolution limit by stimulated emission: stimulated-emission-depletion fluorescence microscopy. Opt Lett. 2009; 19(11):780-2. DOI: 10.1364/ol.19.000780. View

4.
van de Linde S, Loschberger A, Klein T, Heidbreder M, Wolter S, Heilemann M . Direct stochastic optical reconstruction microscopy with standard fluorescent probes. Nat Protoc. 2011; 6(7):991-1009. DOI: 10.1038/nprot.2011.336. View

5.
Roccisana J, Sadler J, Bryant N, Gould G . Sorting of GLUT4 into its insulin-sensitive store requires the Sec1/Munc18 protein mVps45. Mol Biol Cell. 2013; 24(15):2389-97. PMC: 3727931. DOI: 10.1091/mbc.E13-01-0011. View