» Articles » PMID: 39697501

Comparison of Full-Field Digital Mammography with Synthesized Mammography from Tomosynthesis in a Diagnostic Population: Prospective Study

Overview
Publisher Thieme
Specialty Radiology
Date 2024 Dec 19
PMID 39697501
Authors
Affiliations
Soon will be listed here.
Abstract

 Synthesized mammography (SM) refers to two-dimensional (2D) images derived from the digital breast tomosynthesis (DBT) data. It can reduce the radiation dose and scan duration when compared with conventional full-field digital mammography (FFDM) plus tomosynthesis.  To compare the diagnostic performance of 2D FFDM with synthetic mammograms obtained from DBT in a diagnostic population.  A total of 1,468 mammograms with both FFDM and SM + DBT images were obtained and analyzed over 2 years, after obtaining approval from the institute ethics committee. The images were reported and compared as per the 2013 American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) lexicon in terms of breast density, morphological features of mass, calcifications, and presence of asymmetry or architectural distortion followed by the BI-RADS category. The agreement between the two modalities was studied using the Kappa value, and the radiation exposure dose was recorded in both groups.  FFDM and SM + DBT showed strong agreement for breast density, mass characteristics, and detection of calcifications (kappa > 0.8). Downstaging of breast density and mass density were seen by SM + DBT without any statistically significant difference. The nipple-areola complex visualization was poor in SM (50.34 vs. 76.29% in FFDM), and there were SM-specific artifacts mainly related to the reconstruction algorithm. The radiation dose was higher with SM.  FFDM has comparable performance to SM + DBT in diagnostic setup. The latter may be particularly helpful in patients with dense breasts.

References
1.
Hofvind S, Hovda T, Holen A, Lee C, Albertsen J, Bjorndal H . Digital Breast Tomosynthesis and Synthetic 2D Mammography versus Digital Mammography: Evaluation in a Population-based Screening Program. Radiology. 2018; 287(3):787-794. DOI: 10.1148/radiol.2018171361. View

2.
Ab Mumin N, Rahmat K, Fadzli F, Ramli M, Westerhout C, Ramli N . Diagnostic Efficacy of Synthesized 2D Digital Breast Tomosynthesis in Multi-ethnic Malaysian Population. Sci Rep. 2019; 9(1):1459. PMC: 6365555. DOI: 10.1038/s41598-018-37451-4. View

3.
Simon K, Dodelzon K, Drotman M, Levy A, Arleo E, Askin G . Accuracy of Synthetic 2D Mammography Compared With Conventional 2D Digital Mammography Obtained With 3D Tomosynthesis. AJR Am J Roentgenol. 2019; 212(6):1406-1411. DOI: 10.2214/AJR.18.20520. View

4.
Dhamija E, Gulati M, Deo S, Gogia A, Hari S . Digital Breast Tomosynthesis: an Overview. Indian J Surg Oncol. 2021; 12(2):315-329. PMC: 8272763. DOI: 10.1007/s13193-021-01310-y. View

5.
Duffy S, Tabar L, Yen A, Dean P, Smith R, Jonsson H . Mammography screening reduces rates of advanced and fatal breast cancers: Results in 549,091 women. Cancer. 2020; 126(13):2971-2979. PMC: 7318598. DOI: 10.1002/cncr.32859. View