» Articles » PMID: 31302894

Comparison of the Diagnostic Performance of Synthesized Two-dimensional Mammography and Full-field Digital Mammography Alone or in Combination with Digital Breast Tomosynthesis

Overview
Journal Breast Cancer
Specialty Oncology
Date 2019 Jul 15
PMID 31302894
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate whether digital breast tomosynthesis (DBT) and subsequently generated synthesized mammography (SM) images show a better performance than full-field digital mammography (FFDM) images for diagnosing malignant breast lesions. In addition, the radiation doses for SM using different procedures were compared.

Materials And Methods: This prospective study enrolled 212 women (age ≥ 25 years) with clinically suspicious breast lesions. All participants underwent FFDM and DBT with the same breast compression. Finally, 222 lesions were confirmed by pathological analysis. The mammogram results were evaluated according to the BI-RADS criteria and compared with the pathological results. The diagnostic performances, morphological features and average glandular doses (AGDs) were compared.

Results: In total, 141 malignant lesions and 81 benign lesions were confirmed by pathological analysis. The overall AGD showed no significant difference between FFDM and DBT. Compared with 2D imaging, the AUC values of FFDM plus DBT and SM plus DBT were both significantly different overall (P = 0.0002) and remained significantly different in dense breasts (P < 0.0001). In terms of morphologic characteristics, lesions showed similar morphology between FFDM and SM, while the lesion characteristics were discordant from 2D imaging to DBT in 33 lesions in dense breasts.

Conclusions: Compared to FFDM, 2D SM images generated from DBT had significantly improved diagnostic efficacy for detecting malignant breast lesions without increasing radiation doses. This new procedure is useful for characterizing breast lesions, particularly in dense breasts.

Citing Articles

Comparison of Full-Field Digital Mammography with Synthesized Mammography from Tomosynthesis in a Diagnostic population: Prospective Study.

Dhamija E, Mohan S, Anand R, Ahmad Khan M, Deo S, Hari S Indian J Radiol Imaging. 2024; 35(1):25-34.

PMID: 39697501 PMC: 11651816. DOI: 10.1055/s-0044-1788606.


Diagnostic Efficacy of Five Different Imaging Modalities in the Assessment of Women Recalled at Breast Screening-A Systematic Review and Meta-Analysis.

Akwo J, Hadadi I, Ekpo E Cancers (Basel). 2024; 16(20).

PMID: 39456600 PMC: 11505902. DOI: 10.3390/cancers16203505.


The Japanese breast cancer society clinical practice guidelines for breast cancer screening and diagnosis, 2022 edition.

Kubota K, Nakashima K, Nakashima K, Kataoka M, Inoue K, Goto M Breast Cancer. 2023; 31(2):157-164.

PMID: 37973686 PMC: 10901949. DOI: 10.1007/s12282-023-01521-x.


Prospective Comparison of Synthesized Mammography with DBT and Full-Field Digital Mammography with DBT Uncovers Recall Disagreements That may Impact Cancer Detection.

Huang M, Hess K, Ma J, Santiago L, Scoggins M, Arribas E Acad Radiol. 2021; 29(7):1039-1045.

PMID: 34538550 PMC: 11891884. DOI: 10.1016/j.acra.2021.08.004.


Accuracy of Digital Breast Tomosynthesis for Detecting Breast Cancer in the Diagnostic Setting: A Systematic Review and Meta-Analysis.

Ko M, Park D, Kim S, Ko E, Shin K, Lim W Korean J Radiol. 2021; 22(8):1240-1252.

PMID: 34047504 PMC: 8316775. DOI: 10.3348/kjr.2020.1227.