Optimization and Validation of Multi-echo, Multi-contrast SAGE Acquisition in FMRI

Overview
Date 2024 Oct 25
PMID 39449748
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study was to optimize and validate a multi-contrast, multi-echo fMRI method using a combined spin- and gradient-echo (SAGE) acquisition. It was hypothesized that SAGE-based blood oxygen level-dependent (BOLD) functional MRI (fMRI) will improve sensitivity and spatial specificity while reducing signal dropout. SAGE-fMRI data were acquired with five echoes (2 gradient-echoes, 2 asymmetric spin-echoes, and 1 spin-echo) across 12 protocols with varying acceleration factors, and temporal SNR (tSNR) was assessed. The optimized protocol was then implemented in working memory and vision tasks in 15 healthy subjects. Task-based analysis was performed using individual echoes, quantitative dynamic relaxation times T and T, and echo time-dependent weighted combinations of dynamic signals. These methods were compared to determine the optimal analysis method for SAGE-fMRI. Implementation of a multiband factor of 2 and sensitivity encoding (SENSE) factor of 2.5 yielded adequate spatiotemporal resolution while minimizing artifacts and loss in tSNR. Higher BOLD contrast-to-noise ratio (CNR) and tSNR were observed for SAGE-fMRI relative to single-echo fMRI, especially in regions with large susceptibility effects and for T-dominant analyses. Using a working memory task, the extent of activation was highest with T -weighting, while smaller clusters were observed with quantitative T and T. SAGE-fMRI couples the high BOLD sensitivity from multi-gradient-echo acquisitions with improved spatial localization from spin-echo acquisitions, providing two contrasts for analysis. SAGE-fMRI provides substantial advantages, including improving CNR and tSNR for more accurate analysis.

References
1.
Cohen A, Jagra A, Yang B, Fernandez B, Banerjee S, Wang Y . Detecting Task Functional MRI Activation Using the Multiband Multiecho (MBME) Echo-Planar Imaging (EPI) Sequence. J Magn Reson Imaging. 2020; 53(5):1366-1374. PMC: 10937038. DOI: 10.1002/jmri.27448. View

2.
Hagberg G, Indovina I, Sanes J, Posse S . Real-time quantification of T(2)(*) changes using multiecho planar imaging and numerical methods. Magn Reson Med. 2002; 48(5):877-82. DOI: 10.1002/mrm.10283. View

3.
Norris D, Zysset S, Mildner T, Wiggins C . An investigation of the value of spin-echo-based fMRI using a Stroop color-word matching task and EPI at 3 T. Neuroimage. 2002; 15(3):719-26. DOI: 10.1006/nimg.2001.1005. View

4.
Manhard M, Stockmann J, Liao C, Park D, Han S, Fair M . A multi-inversion multi-echo spin and gradient echo echo planar imaging sequence with low image distortion for rapid quantitative parameter mapping and synthetic image contrasts. Magn Reson Med. 2021; 86(2):866-880. PMC: 8793364. DOI: 10.1002/mrm.28761. View

5.
Fischl B . FreeSurfer. Neuroimage. 2012; 62(2):774-81. PMC: 3685476. DOI: 10.1016/j.neuroimage.2012.01.021. View