A Multi-inversion Multi-echo Spin and Gradient Echo Echo Planar Imaging Sequence with Low Image Distortion for Rapid Quantitative Parameter Mapping and Synthetic Image Contrasts
Overview
Authors
Affiliations
Purpose: Brain imaging exams typically take 10-20 min and involve multiple sequential acquisitions. A low-distortion whole-brain echo planar imaging (EPI)-based approach was developed to efficiently encode multiple contrasts in one acquisition, allowing for calculation of quantitative parameter maps and synthetic contrast-weighted images.
Methods: Inversion prepared spin- and gradient-echo EPI was developed with slice-order shuffling across measurements for efficient acquisition with T , T , and weighting. A dictionary-matching approach was used to fit the images to quantitative parameter maps, which in turn were used to create synthetic weighted images with typical clinical contrasts. Dynamic slice-optimized multi-coil shimming with a B shim array was used to reduce B inhomogeneity and, therefore, image distortion by >50%. Multi-shot EPI was also implemented to minimize distortion and blurring while enabling high in-plane resolution. A low-rank reconstruction approach was used to mitigate errors from shot-to-shot phase variation.
Results: The slice-optimized shimming approach was combined with in-plane parallel-imaging acceleration of 4× to enable single-shot EPI with more than eight-fold distortion reduction. The proposed sequence efficiently obtained 40 contrasts across the whole-brain in just over 1 min at 1.2 × 1.2 × 3 mm resolution. The multi-shot variant of the sequence achieved higher in-plane resolution of 1 × 1 × 4 mm with good image quality in 4 min. Derived quantitative maps showed comparable values to conventional mapping methods.
Conclusion: The approach allows fast whole-brain imaging with quantitative parameter maps and synthetic weighted contrasts. The slice-optimized multi-coil shimming and multi-shot reconstruction approaches result in minimal EPI distortion, giving the sequence the potential to be used in rapid screening applications.
Synthetic MR: Clinical applications in neuroradiology.
Sharma S, Nayak A, Thomas B, Kesavadas C Neuroradiology. 2025; .
PMID: 39888426 DOI: 10.1007/s00234-025-03547-8.
Kilpattu Ramaniharan A, Pednekar A, Parikh N, Nagaraj U, Manhard M Pediatr Radiol. 2024; 55(2):312-323.
PMID: 39692886 DOI: 10.1007/s00247-024-06113-1.
Optimization and validation of multi-echo, multi-contrast SAGE acquisition in fMRI.
Keeling E, Bergamino M, Ragunathan S, Quarles C, Newton A, Stokes A Imaging Neurosci (Camb). 2024; 2:1-20.
PMID: 39449748 PMC: 11497078. DOI: 10.1162/imag_a_00217.
Manhard M, Kilpattu Ramaniharan A, Tkach J, Trout A, Dillman J, Pednekar A J Magn Reson Imaging. 2024; 61(4):1925-1936.
PMID: 39192381 PMC: 11896940. DOI: 10.1002/jmri.29584.
Benjamini D, Bouhrara M, Komlosh M, Iacono D, Perl D, Brody D Front Phys. 2023; 9.
PMID: 37408700 PMC: 10321473. DOI: 10.3389/fphy.2021.737374.