» Articles » PMID: 39428407

Toxicity of Nuclear-localized GFP in Reporter Mice

Overview
Journal Sci Rep
Specialty Science
Date 2024 Oct 20
PMID 39428407
Authors
Affiliations
Soon will be listed here.
Abstract

Various techniques using fluorescent reporter probes have been developed, such as GFP transgenic mouse lines that are used to detect spatial-temporal expression levels of genes. Although GFP expression is largely considered non-toxic, recent reports have indicated that under certain conditions GFP can display cellular toxicity. We hereby report the nuclear toxicity of H2B-GFP using a K14 specific Tet-on reporter mouse system. Using this system, GFP accumulates in the nucleus of all K14 expressing cells, such as the ocular surface epithelia and ocular adnexa. Expression of high levels of nuclear GFP during embryonic stages led to an eye open-at-birth (EOB) phenotype and abnormal ocular adnexa development and during adult and aging stages showed notable toxicity to ocular tissues. Other tissues, such as skin, also presented multiple defects associated with H2B-GFP expression. This toxicity was found to be concentration dependent, with homozygous mice presenting extremely high toxicity, while heterozygous mice presented limited toxicity. Upon induction, the accumulation of H2B-GFP in the nucleus of homozygous mice led to apoptosis within 2 weeks. This study therefore shows that although the use of nuclear GFP reporter mice is a valuable tool, at high levels, nuclear GFP can be toxic, leading to cell death and affecting tissue function.

References
1.
Shimomura O, Johnson F, Saiga Y . Extraction, purification and properties of aequorin, a bioluminescent protein from the luminous hydromedusan, Aequorea. J Cell Comp Physiol. 1962; 59:223-39. DOI: 10.1002/jcp.1030590302. View

2.
Prasher D, Eckenrode V, Ward W, Prendergast F, Cormier M . Primary structure of the Aequorea victoria green-fluorescent protein. Gene. 1992; 111(2):229-33. DOI: 10.1016/0378-1119(92)90691-h. View

3.
Chalfie M, Tu Y, Euskirchen G, Ward W, Prasher D . Green fluorescent protein as a marker for gene expression. Science. 1994; 263(5148):802-5. DOI: 10.1126/science.8303295. View

4.
Li X, Zhang G, Ngo N, Zhao X, Kain S, Huang C . Deletions of the Aequorea victoria green fluorescent protein define the minimal domain required for fluorescence. J Biol Chem. 1997; 272(45):28545-9. DOI: 10.1074/jbc.272.45.28545. View

5.
Lukyanov K . Fluorescent proteins for a brighter science. Biochem Biophys Res Commun. 2022; 633:29-32. DOI: 10.1016/j.bbrc.2022.08.089. View