» Articles » PMID: 39391625

Highly Sensitive Colorimetric Detection of Cd(ii) Based on Silica Sol Modified with Dithizone and Cationic Surfactant

Overview
Journal RSC Adv
Specialty Chemistry
Date 2024 Oct 11
PMID 39391625
Authors
Affiliations
Soon will be listed here.
Abstract

The cadmium ion (Cd) is highly poisonous and nondegradable and easily bioaccumulates through the food chain. Therefore, it is crucial to develop cost-effective chemical sensors for Cd with fast response time, high selectivity, and very low detection limits. In this study, a colorimetric sensor for the determination of Cd was fabricated by modifying silica sol with dodecyltrimethylammonium bromide (DTAB) and dithizone (DZ). Cd formed a complex with DZ, changing the solution color immediately from purple to orange prior to detection using ultraviolet-visible spectrophotometry and a customized Cd analyzer for the precipitate. Under the optimum conditions, the developed Cd sensor had a linear range of 0.01-0.25 mg L, a low limit of detection of 5.0 μg L, and outstanding repeatability. This sensor also showed good precision, with the relative standard deviations of less than 2.59% and 3.24% for the intra- and inter-day data, respectively. The proposed colorimetric method was successfully applied to determine Cd in environmental water samples, and the results were comparable to those obtained using standard atomic absorption spectrometry. Moreover, quantitative analysis was conducted using the customized Cd analyzer to estimate the color intensity change, without requiring sophisticated scientific instruments. This colorimetric sensor can be used for the portable, cost-effective, and rapid on-site detection of Cd in environmental water samples.

References
1.
Zougagh M, Garcia de Torres A, Cano Pavon J . Determination of cadmium in water by ICP-AES with on-line adsorption preconcentration using DPTH-gel and TS-gel microcolumns. Talanta. 2008; 56(4):753-61. DOI: 10.1016/s0039-9140(01)00605-1. View

2.
Goudarzi N . Solvent microextraction-flame atomic absorption spectrometry (SME-FAAS) for determination of ultratrace amounts of cadmium in meat and fish samples. J Agric Food Chem. 2009; 57(3):1099-104. DOI: 10.1021/jf8027057. View

3.
Zhang N, Shen K, Yang X, Li Z, Zhou T, Zhang Y . Simultaneous determination of arsenic, cadmium and lead in plant foods by ICP-MS combined with automated focused infrared ashing and cold trap. Food Chem. 2018; 264:462-470. DOI: 10.1016/j.foodchem.2018.05.058. View

4.
Wu L, Fu X, Liu H, Li J, Song Y . Comparative study of graphene nanosheet- and multiwall carbon nanotube-based electrochemical sensor for the sensitive detection of cadmium. Anal Chim Acta. 2014; 851:43-8. DOI: 10.1016/j.aca.2014.08.021. View

5.
Accioni F, Garcia-Gomez D, Girela E, Rubio S . SUPRAS extraction approach for matrix-independent determination of amphetamine-type stimulants by LC-MS/MS. Talanta. 2018; 182:574-582. DOI: 10.1016/j.talanta.2018.02.039. View