» Articles » PMID: 18968552

Determination of Cadmium in Water by ICP-AES with On-line Adsorption Preconcentration Using DPTH-gel and TS-gel Microcolumns

Overview
Journal Talanta
Publisher Elsevier
Specialty Chemistry
Date 2008 Oct 31
PMID 18968552
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Two flow injection inductively coupled plasma atomic emission spectrometric methods for the preconcentration and determination of trace amounts of cadmium in sea-water and waste-water samples are described based on the adsorption of the metal ion on a micro-column placed in the injection valve of the FI manifold and packed with silica gel funtionalised with 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH-gel) and silica gel functionalised with methylthiosalicylate (TS-gel), respectively. Various parameters and chemical variables affecting the preconcentration and determination of this metal by ICP-AES are evaluated. The DPTH-gel preconcentration method has a linear calibration range from 5 to at least 100 ng ml(-1) of cadmium, with a R.S.D. of 1.1% for ten independent analyses of 100 ng ml(-1), a detection limit of 1.1 ng ml(-1) and a throughput of 40 samples per hour using a 60 s preconcentration time. The TS-gel preconcentration method shows a linear range between 10 and 100 ng ml(-1), with a R.S.D. of 2.5% for ten independent analyses of 100 ng ml(-1), a detection limit of 4.3 ng ml(-1) and a sample throughput of 24 samples per hour for a preconcentration time of 120 s. Validation was carried out against a certified reference water sample and by determining the analyte content in spiked synthetic sea-water, sea-water and waste-water.

Citing Articles

Highly sensitive colorimetric detection of Cd(ii) based on silica sol modified with dithizone and cationic surfactant.

Litluechai A, Prompa A, Uppachai P, Jarernboon W, Butwong N, Mukdasai S RSC Adv. 2024; 14(44):32101-32108.

PMID: 39391625 PMC: 11466134. DOI: 10.1039/d4ra03983a.


The Graphene/l-Cysteine/Gold-Modified Electrode for the Differential Pulse Stripping Voltammetry Detection of Trace Levels of Cadmium.

Song Y, Bian C, Tong J, Li Y, Xia S Micromachines (Basel). 2018; 7(6).

PMID: 30404277 PMC: 6189839. DOI: 10.3390/mi7060103.


Silica glass modified with flavonoid derivatives for preconcentration of some toxic metal ions in water samples and their determination with ICP-MS.

Hassanien M Environ Monit Assess. 2009; 167(1-4):587-98.

PMID: 19633914 DOI: 10.1007/s10661-009-1075-6.