» Articles » PMID: 39347003

Optimizing Spatial Accuracy in Electroencephalography Reconstruction Through Diffuse Optical Tomography Priors in the Auditory Cortex

Overview
Specialty Radiology
Date 2024 Sep 30
PMID 39347003
Authors
Affiliations
Soon will be listed here.
Abstract

Diffuse optical tomography (DOT) enhances the localization accuracy of neural activity measured with electroencephalography (EEG) while preserving EEG's high temporal resolution. However, the spatial resolution of reconstructed activity diminishes for deeper neural sources. In this study, we analyzed DOT-enhanced EEG localization of neural sources modeled at depths ranging from 11-25 mm in simulations. Our findings reveal systematic biases in reconstructed depth related to DOT channel length. To address this, we developed a data-informed method for selecting DOT channels to improve the spatial accuracy of DOT-enhanced EEG reconstruction. Using our method, the average absolute reconstruction depth errors of DOT reconstruction across all depths are 0.9 ± 0.6 mm, 1.2 ± 0.9 mm, and 1.2 ± 1.1 mm under noiseless, low-level noise, and high-level noise conditions, respectively. In comparison, using fixed channel lengths resulted in errors of 2.6 ± 1.5 mm, 5.0 ± 2.6 mm, and 7.3 ± 4.5 mm under the same conditions. Consequently, our method improved the depth accuracy of DOT reconstructions and facilitated the use of more accurate spatial priors for EEG reconstructions, enhancing the overall precision of the technique.

Citing Articles

Diffuse Optical Spectroscopy: Technology and Applications: introduction to the feature issue.

OSullivan T, Dehghani H, Re R Biomed Opt Express. 2024; 15(11):6516-6520.

PMID: 39553860 PMC: 11563346. DOI: 10.1364/BOE.542635.

References
1.
Garn S, Selby S, Young R . Scalp thickness and the fat-loss theory of balding. AMA Arch Derm Syphilol. 1954; 70(5):601-8. DOI: 10.1001/archderm.1954.01540230051006. View

2.
Cao J, Bulger E, Shinn-Cunningham B, Grover P, Kainerstorfer J . Diffuse optical tomography spatial prior for EEG source localization in human visual cortex. Neuroimage. 2023; 277:120210. DOI: 10.1016/j.neuroimage.2023.120210. View

3.
Fan W, Dehghani H, Eggebrecht A . Investigation of effect of modulation frequency on high-density diffuse optical tomography image quality. Neurophotonics. 2021; 8(4):045002. PMC: 8612746. DOI: 10.1117/1.NPh.8.4.045002. View

4.
Eames M, Dehghani H . Wavelength dependence of sensitivity in spectral diffuse optical imaging: effect of normalization on image reconstruction. Opt Express. 2008; 16(22):17780-91. DOI: 10.1364/oe.16.017780. View

5.
Aine C . A conceptual overview and critique of functional neuroimaging techniques in humans: I. MRI/FMRI and PET. Crit Rev Neurobiol. 1995; 9(2-3):229-309. View