Accuracy of the WatchBP Office Central As a Type 2 Device for Non-invasive Estimation of Central Aortic Blood Pressure in Children and Adolescents

Overview
Journal J Hum Hypertens
Date 2024 Sep 13
PMID 39271785
Authors
Affiliations
Soon will be listed here.
Abstract

High blood pressure (BP) in childhood is a recognised precursor of elevated cardiovascular risk in adulthood. Brachial BP is normally used for clinical decision making, but central BP may be a better marker of pressure load on the heart. There is a paucity of validated non-invasive, automated devices for estimating central BP in children and adolescents. In this study, we compared the WatchBP Office Central (a Type 2 central pressure estimation device) against a high-fidelity micromanometer in the ascending aorta of anaesthetised patients undergoing clinically-indicated catheterisation (n = 15, age 4-16 years). As a secondary aim, central systolic BP (cSBP) was also compared to two non-invasive estimation methods in 34 awake patients undergoing routine cardiac MRI (age 10-18 years). WatchBP substantially overestimated cSBP compared to the intra-arterial gold-standard reference (26.1 ± 7.4 mmHg), and recruitment was terminated at n = 11 (included in the analysis) due to high statistical certainty that the device would not pass the validation criteria of 5±8 mmHg. WatchBP cSBP was also substantially higher than values obtained from a phase contrast MRI method (11.8 ± 7.9 mmHg) and the SphygmoCor XCEL (13.5 ± 8.9 mmHg) in the awake patient group, which translate to 21-23 mmHg on average after accounting for known/estimated biases in these non-invasive comparators. Compared with invasive central diastolic and systolic BPs, the brachial measures from WatchBP yielded errors of 0.1 ± 5.6 and 12.5 ± 6.0 mmHg respectively. We conclude that the WatchBP substantially overestimates cSBP in children and adolescents. These findings reinforce the need for central BP-measuring devices to be further developed and validated in this population.

References
1.
Urbina E, Dolan L, McCoy C, Khoury P, Daniels S, Kimball T . Relationship between elevated arterial stiffness and increased left ventricular mass in adolescents and young adults. J Pediatr. 2011; 158(5):715-21. PMC: 3075322. DOI: 10.1016/j.jpeds.2010.12.020. View

2.
Ding F, Fan W, Zhang R, Zhang Q, Li Y, Wang J . Validation of the noninvasive assessment of central blood pressure by the SphygmoCor and Omron devices against the invasive catheter measurement. Am J Hypertens. 2011; 24(12):1306-11. DOI: 10.1038/ajh.2011.145. View

3.
Van Bortel L, Balkestein E, van der Heijden-Spek J, Vanmolkot F, Staessen J, Kragten J . Non-invasive assessment of local arterial pulse pressure: comparison of applanation tonometry and echo-tracking. J Hypertens. 2001; 19(6):1037-44. DOI: 10.1097/00004872-200106000-00007. View

4.
Smulyan H, Siddiqui D, Carlson R, London G, Safar M . Clinical utility of aortic pulses and pressures calculated from applanated radial-artery pulses. Hypertension. 2003; 42(2):150-5. DOI: 10.1161/01.HYP.0000084051.34269.A9. View

5.
Jacobs Jr D, Woo J, Sinaiko A, Daniels S, Ikonen J, Juonala M . Childhood Cardiovascular Risk Factors and Adult Cardiovascular Events. N Engl J Med. 2022; 386(20):1877-1888. PMC: 9563825. DOI: 10.1056/NEJMoa2109191. View