Prospective Evaluation of a Method for Estimating Ascending Aortic Pressure from the Radial Artery Pressure Waveform

Overview
Journal Hypertension
Date 2001 Oct 20
PMID 11641312
Citations 315
Authors
Affiliations
Soon will be listed here.
Abstract

Pressure wave reflection in the upper limb causes amplification of the arterial pulse so that radial systolic and pulse pressures are greater than in the ascending aorta. Wave transmission properties in the upper limbs (in contrast to the descending aorta and lower limbs) change little with age, disease, and drug therapy in adult humans. Such consistency has led to use of a generalized transfer function to synthesize the ascending aortic pressure pulse from the radial pulse. Validity of this approach was tested for estimation of aortic systolic, diastolic, pulse, and mean pressures from the radial pressure waveform. Ascending aortic and radial pressure waveforms were recorded simultaneously at cardiac surgery, before initiation of cardiopulmonary bypass, with matched, fluid-filled manometer systems in 62 patients under control conditions and during nitroglycerin infusion. Aortic pressure pulse waves, generated from the radial pulse, showed agreement with the measured aortic pulse waves with respect to systolic, diastolic, pulse, and mean pressures, with mean differences <1 mm Hg. Control differences in Bland-Altman plots for mean+/-SD in mm Hg were systolic, 0.0+/-4.4; diastolic, 0.6+/-1.7; pulse, -0.7+/-4.2; and mean pressure, -0.5+/-2.0. For nitroglycerin infusion, differences respectively were systolic, -0.2+/-4.3; diastolic, 0.6+/-1.7; pulse, -0.8+/-4.1; and mean pressure, -0.4+/-1.8. Differences were within specified limits of the Association for the Advancement of Medical Instrumentation SP10 criteria. In contrast, differences between recorded radial and aortic systolic and pulse pressures were well outside the criteria (respectively, 15.7+/-8.4 and 16.3+/-8.5 for control and 14.5+/-7.3 and 15.1+/-7.3 mm Hg for nitroglycerin). Use of a generalized transfer function to synthesize radial artery pressure waveforms can provide substantially equivalent values of aortic systolic, pulse, mean, and diastolic pressures.

Citing Articles

Research and development of the pulse acquisition system and the pulse biomimetic reproduction system.

Kai Y, Yunjing M, Shen G, Heng L, Bin X J Tradit Chin Med. 2025; 45(1):213-220.

PMID: 39957176 PMC: 11764930. DOI: 10.19852/j.cnki.jtcm.2025.01.021.


Short-term pulse pressure variability: a novel prognostic marker and therapeutic target in patients with vascular Ehlers-Danlos syndrome? Preliminary results from a pilot study.

Buso G, Gatta R, Corvini F, Laera N, Agabiti-Rosei C, Paini A Hypertens Res. 2025; .

PMID: 39953236 DOI: 10.1038/s41440-025-02135-w.


Association of Total Mortality and Cardiovascular Endpoints With the Timing of the First and Second Systolic Peak of the Aortic Pulse Wave.

Cheng Y, An D, Aparicio L, Huang Q, Yu Y, Sheng C J Clin Hypertens (Greenwich). 2025; 27(1):e14962.

PMID: 39821625 PMC: 11771774. DOI: 10.1111/jch.14962.


Clinical validation of a wearable ultrasound sensor of blood pressure.

Zhou S, Park G, Longardner K, Lin M, Qi B, Yang X Nat Biomed Eng. 2024; .

PMID: 39567702 DOI: 10.1038/s41551-024-01279-3.


Validation of Noninvasive Derivation of the Central Aortic Pressure Waveform from Fingertip Photoplethysmography Using a Novel Selective Transfer Function Method.

Cox J, Akeila E, Avolio A, Butlin M, Liao C, Bentley G Pulse (Basel). 2024; 12(1):95-105.

PMID: 39479582 PMC: 11521451. DOI: 10.1159/000540666.