Reliability of the Instrumented Modified Clinical Test of Sensory Interaction on Balance Using a Virtual Balance Device

Overview
Journal Int J Exerc Sci
Date 2024 Sep 11
PMID 39257646
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study was to evaluate the test-retest reliability of the instrumented version of the modified Clinical Test of Sensory Interaction on Balance (i-mCTSIB) using the VirtuSense VirtuBalance System™ (VSTBalance), a virtual balance device, in healthy young adults. Fifty-four subjects aged 20-27 years (Mean age 23.07, SD ± 1.6), participated in the study. A one-group design was utilized. Three trials of the i-mCTSIB were performed on two separate days to measure the mean sway velocity of the trunk under four conditions. Within-day reliability of trials 1-3 was estimated with intraclass correlation coefficients (ICC) and between-day reliability was estimated using the averages of trials 1-3 on day 1 and day 2 (ICC). Within-day reliability was moderate on day 1 (ICC = 0.511-0.672) and day 2 (ICC = 0.539 -0.677). Between-day reliability was moderate to good (ICC = 0.705-0.810). The lower bounds of the confidence intervals of within-day reliability estimates were 0.341-0.548, while the lower bounds of the confidence interval for the between-day reliability estimates were 0.390-0.671. Reliability of the VSTBalance for balance assessment using the i-mCTSIB test is moderate to good. Between-day reliability was higher than within-day reliability. When using the VSTBalance to assess balance with the i-mCTSIB, clinicians should provide practice of each condition contained in the test to improve reliability. The higher between-day reliability as compared to within-day reliability suggests that clinicians should use the averages of three trials when assessing balance performance change across time for each condition of the i-mCTSIB test when assessing balance using the VSTBalance.

References
1.
Alsalaheen B, Haines J, Yorke A, Broglio S . Reliability and Construct Validity of Limits of Stability Test in Adolescents Using a Portable Forceplate System. Arch Phys Med Rehabil. 2015; 96(12):2194-200. DOI: 10.1016/j.apmr.2015.08.418. View

2.
Ghahramani M, Stirling D, Naghdy F, Naghdy G, Potter J . Body postural sway analysis in older people with different fall histories. Med Biol Eng Comput. 2018; 57(2):533-542. DOI: 10.1007/s11517-018-1901-5. View

3.
Miner D, Harper B, Glass S . Validity of Postural Sway Assessment on the Biodex BioSway™ Compared With the NeuroCom Smart Equitest. J Sport Rehabil. 2020; 30(3):516-520. DOI: 10.1123/jsr.2020-0227. View

4.
Hageman P, Leibowitz J, Blanke D . Age and gender effects on postural control measures. Arch Phys Med Rehabil. 1995; 76(10):961-5. DOI: 10.1016/s0003-9993(95)80075-1. View

5.
Antoniadou E, Kalivioti X, Stolakis K, Koloniari A, Megas P, Tyllianakis M . Reliability and validity of the mCTSIB dynamic platform test to assess balance in a population of older women living in the community. J Musculoskelet Neuronal Interact. 2020; 20(2):185-193. PMC: 7288384. View