Electrochemical Sensors Based on the Composite of Reduced Graphene Oxide and a Multiwalled Carbon Nanotube-modified Glassy Carbon Electrode for Simultaneous Detection of Hydroquinone, Dopamine, and Uric Acid

Overview
Journal RSC Adv
Specialty Chemistry
Date 2024 Sep 4
PMID 39228754
Authors
Affiliations
Soon will be listed here.
Abstract

Using a simple drop-casting technique, we successfully fabricated a sensitive electrochemical sensor based on the composite of reduced graphene oxide (RGO) and multiwalled carbon nanotubes (MWCNT) deposited on the surface of a glassy carbon electrode (GCE) for individual and simultaneous measurements of hydroquinone (HQ), dopamine (DA), and uric acid (UA). The nanocomposite of RGO/MWCNT was further characterized in terms of its structural properties, surface morphology, and topography using Raman, FT-IR spectroscopy, SEM, HRTEM, and AFM. Then, the proposed sensor for simultaneous measurement of HQ, DA, and UA based on RGO/MWCNT-modified GCE was investigated for its electrochemical behavior and electroanalytical performances using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV). In addition, the composition ratio between RGO and MWCT was 1 : 1 showing the highest electrochemical response for simultaneous detection of HQ, DA, and UA. Owing to the synergistic effect between RGO and MWCNT leading to excellent conductivity properties, the proposed sensor exhibited improved electrochemical response at pH 7 toward the oxidation processes of HQ, DA, and UA on the surface of modified electrode. The proposed sensor demonstrated three well-defined anodic peaks of these analytes with their linear concentrations ranges of 3.0-150.0 μM for HQ, 4.0-100.0 μM for DA, and 2.0-70.0 μM for UA. The limit of detection values for the simultaneous detection of HQ, DA, and UA were found as follows 0.400 ± 0.014, 0.500 ± 0.006, and 0.300 ± 0.016 μM, respectively. The additional features of this proposed sensor are high reproducibility and stability for the simultaneous detection of HQ, DA, and UA with negligible interference effect from interferents such as Mg, K, Cl, ascorbic acid, and glucose. An acceptable percentage of recovery was also shown by this sensor for simultaneous measurements of HQ, DA, and UA using 6 samples of human urine. In summary, the RGO/MWCNT nanocomposite has been shown to be a promising platform for rapid, simple, and reliable determination of simultaneous measurements of HQ, DA, and UA in practical applications.

References
1.
Okhay O, Tkach A . Graphene/Reduced Graphene Oxide-Carbon Nanotubes Composite Electrodes: From Capacitive to Battery-Type Behaviour. Nanomaterials (Basel). 2021; 11(5). PMC: 8151991. DOI: 10.3390/nano11051240. View

2.
Chen F, Wang J, Chen L, Lin H, Han D, Bao Y . A Wearable Electrochemical Biosensor Utilizing Functionalized TiCT MXene for the Real-Time Monitoring of Uric Acid Metabolite. Anal Chem. 2024; 96(9):3914-3924. DOI: 10.1021/acs.analchem.3c05672. View

3.
Bagheri H, Hajian A, Rezaei M, Shirzadmehr A . Composite of Cu metal nanoparticles-multiwall carbon nanotubes-reduced graphene oxide as a novel and high performance platform of the electrochemical sensor for simultaneous determination of nitrite and nitrate. J Hazard Mater. 2016; 324(Pt B):762-772. DOI: 10.1016/j.jhazmat.2016.11.055. View

4.
Li S, Ali S, Zuhra Z, Shen H, Qiu J, Zeng Y . Cobalt Encapsulated in Nitrogen-Doped Graphite-like Shells as Efficient Catalyst for Selective Oxidation of Arylalkanes. Molecules. 2024; 29(1). PMC: 10779642. DOI: 10.3390/molecules29010065. View

5.
Rybina A, Thaler B, Kramer R, Herten D . Monitoring hydroquinone-quinone redox cycling by single molecule fluorescence spectroscopy. Phys Chem Chem Phys. 2014; 16(36):19550-5. DOI: 10.1039/c4cp02640c. View