» Articles » PMID: 35287218

A Facile Electrochemical Sensor Based on a Composite of Electrochemically Reduced Graphene Oxide and a PEDOT:PSS Modified Glassy Carbon Electrode for Uric Acid Detection

Overview
Journal Anal Sci
Publisher Springer
Specialty Chemistry
Date 2022 Mar 14
PMID 35287218
Authors
Affiliations
Soon will be listed here.
Abstract

A glassy carbon electrode modified with electrochemically reduced graphene oxide (ErGO) and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) was developed for uric acid determination with dopamine as interference in artificial saliva. The electrochemical performance of the fabricated electrode was studied using both techniques of cyclic voltammetry (CV) and differential pulse voltammetry (DPV), under optimized conditions. Using DPV, the sensor based on ErGO/PEDOT:PSS modified GCE displayed a linear relationship in the concentration ranges of 10-100 µM for uric acid. This uric acid sensor exhibited a high sensitivity with detection limits of 1.08 µM and quantitation limit of 3.61 µM. This sensor also showed good reproducibility for uric acid detection in artificial saliva in 5 consecutive days of measurements. This device was successfully used to analyze uric acid in artificial saliva as well as in a human saliva sample using the standard addition method.

Citing Articles

Compensation for Matrix Effects in High-Dimensional Spectral Data Using Standard Addition.

Khanonkin E, Schechter I, Dattner I Sensors (Basel). 2025; 25(3).

PMID: 39943250 PMC: 11819934. DOI: 10.3390/s25030612.


Electrochemical sensors based on the composite of reduced graphene oxide and a multiwalled carbon nanotube-modified glassy carbon electrode for simultaneous detection of hydroquinone, dopamine, and uric acid.

Wahyuni W, Hasnawati Taalia S, Akbar A, Elvira B, Irkham , Rahmawati I RSC Adv. 2024; 14(38):27999-28016.

PMID: 39228754 PMC: 11369672. DOI: 10.1039/d4ra05537c.


Electrochemical Sensors based on Gold-Silver Core-Shell Nanoparticles Combined with a Graphene/PEDOT:PSS Composite Modified Glassy Carbon Electrode for Paraoxon-ethyl Detection.

Wahyuni W, Putra B, Rahman H, Anindya W, Hardi J, Rustami E ACS Omega. 2024; 9(2):2896-2910.

PMID: 38250352 PMC: 10795144. DOI: 10.1021/acsomega.3c08349.


Electrochemical detection of uric acid in human serum based on ultrasmall TaO nanoparticle anchored Pt atom with ultrahigh uricase and catalase activities.

Nana L, Ruiyi L, Guangli W, Zaijun L Mikrochim Acta. 2023; 190(5):195.

PMID: 37106244 DOI: 10.1007/s00604-023-05758-3.


Fabrication of Hybrid Electrodes by Laser-Induced Forward Transfer for the Detection of Cu Ions.

Bonciu A, Andrei F, Palla-Papavlu A Materials (Basel). 2023; 16(4).

PMID: 36837372 PMC: 9959881. DOI: 10.3390/ma16041744.


References
1.
He J, Jin G, Chen Q, Wang Y . A quercetin-modified biosensor for amperometric determination of uric acid in the presence of ascorbic acid. Anal Chim Acta. 2007; 585(2):337-43. DOI: 10.1016/j.aca.2007.01.004. View

2.
Wang Q, Wen X, Kong J . Recent Progress on Uric Acid Detection: A Review. Crit Rev Anal Chem. 2019; 50(4):359-375. DOI: 10.1080/10408347.2019.1637711. View

3.
Wang X, Yao Q, Tang X, Zhong H, Qiu P, Wang X . A highly selective and sensitive colorimetric detection of uric acid in human serum based on MoS-catalyzed oxidation TMB. Anal Bioanal Chem. 2018; 411(4):943-952. DOI: 10.1007/s00216-018-1524-6. View

4.
Jin D, Seo M, The Huy B, Pham Q, Conte M, Thangadurai D . Quantitative determination of uric acid using CdTe nanoparticles as fluorescence probes. Biosens Bioelectron. 2015; 77:359-65. DOI: 10.1016/j.bios.2015.09.057. View

5.
Ratautaite V, Samukaite-Bubniene U, Plausinaitis D, Boguzaite R, Balciunas D, Ramanaviciene A . Molecular Imprinting Technology for Determination of Uric Acid. Int J Mol Sci. 2021; 22(9). PMC: 8126139. DOI: 10.3390/ijms22095032. View