Background And Purpose: Radiotherapy trial quality assurance (RT QA) is crucial for ensuring the safe and reliable delivery of radiotherapy trials, and minimizing inter-institutional variations. While previous studies focused on outlining and planning quality assurance (QA), this work explores the process of Image-Guided Radiotherapy (IGRT), and adaptive radiotherapy. This study presents findings from during-accrual QA in the RAIDER trial, evaluating concordance between online and offline plan selections for bladder cancer participants undergoing adaptive radiotherapy. RAIDER had two seamless stages; stage 1 assessed adherence to dose constraints of dose escalated radiotherapy (DART) and stage 2 assessed safety. The RT QA programme was updated from stage 1 to stage 2.

Materials And Methods: Data from all participants in the adaptive arms (standard dose adaptive radiotherapy (SART) and DART) of the trial was requested (33 centres across the UK, Australia and New Zealand). Data collection spanned September 2015 to December 2022 and included the plans selected online, on Cone-Beam Computed Tomography (CBCT) data. Concordance with the plans selected offline by the independent RT QA central reviewer was evaluated.

Results: Analysable data was received for 72 participants, giving a total of 884 CBCTs. The overall concordance rate was 83% (723/884). From stage 1 to stage 2 the concordance in the plans selected improved from 75% (369/495) to 91% (354/389).

Conclusion: During-accrual IGRT QA positively influenced plan selection concordance, highlighting the need for ongoing support when introducing a new technique. Overall, it contributes to advancing the understanding and implementation of QA measures in adaptive radiotherapy trials.

Citing Articles

Proton beam therapy image-guided radiotherapy training for RTTs - Experience from a single institution.

Kottakunnan J, Shoraka S, Dodd A, Kilkenny M, Petty S, Osborn K Tech Innov Patient Support Radiat Oncol. 2025; 33():100299.

PMID: 39850231 PMC: 11755385. DOI: 10.1016/j.tipsro.2024.100299.


Clinical implementation of RTT-only CBCT-guided online adaptive focal radiotherapy for bladder cancer.

Goudschaal K, Azzarouali S, Visser J, Admiraal M, Wiersma J, van Wieringen N Clin Transl Radiat Oncol. 2024; 50:100884.

PMID: 39559697 PMC: 11570400. DOI: 10.1016/j.ctro.2024.100884.

References
1.
Webster A, Hafeez S, Lewis R, Griffins C, Warren-Oseni K, Patel E . The Development of Therapeutic Radiographers in Imaging and Adaptive Radiotherapy Through Clinical Trial Quality Assurance. Clin Oncol (R Coll Radiol). 2021; 33(7):461-467. DOI: 10.1016/j.clon.2021.02.009. View

2.
McNair H, Franks K, van Herk M . On Target 2: Updated Guidance for Image-guided Radiotherapy. Clin Oncol (R Coll Radiol). 2021; 34(3):187-188. DOI: 10.1016/j.clon.2021.10.002. View

3.
McNair H, Hafeez S, Taylor H, Lalondrelle S, McDonald F, Hansen V . Radiographer-led plan selection for bladder cancer radiotherapy: initiating a training programme and maintaining competency. Br J Radiol. 2015; 88(1048):20140690. DOI: 10.1259/bjr.20140690. View

4.
Joyce E, Jackson M, Skok J, Rock B, McNair H . What do we want? Training! When do we want it? Now? A training needs analysis for adaptive radiotherapy for therapeutic radiographers. Radiography (Lond). 2023; 29(4):818-826. DOI: 10.1016/j.radi.2023.05.015. View

5.
Taylor P, Miles E, Hoffmann L, Kelly S, Kry S, Moller D . Prioritizing clinical trial quality assurance for photons and protons: A failure modes and effects analysis (FMEA) comparison. Radiother Oncol. 2023; 182:109494. DOI: 10.1016/j.radonc.2023.109494. View