Objective: The incidence of periprosthetic fractures after total hip arthroplasty using a short tapered-wedge stem is high. Callus formation preceding this fracture, which indicates postoperative stress fracture around the stem, has been reported. However, previous studies on postoperative callus are limited. Hence, the current study aimed to evaluate the prevalence and risk factors of postoperative callus after total hip arthroplasty with a short tapered-wedge stem.

Materials And Methods: This retrospective study included 127 patients who underwent total hip arthroplasty using a cementless short tapered-wedge stem. The depth of stem insertion was measured as the distance from the lateral corner of the stem to the most medial point of the lesser trochanter along the body axis. Postoperative callus was defined as a bridging callus on the lateral femoral cortex at the distal end of the porous coating of the stem. Plain radiography was performed before surgery and immediately and at 1, 3, and 6 months after surgery to assess postoperative callus. Univariate and multivariate logistic regression analyses were performed to identify the risk factors for PC.

Results: In total, 60 (47.2%) of 127 patients presented with postoperative callus. Multivariate logistic regression analysis with postoperative callus as the dependent variable revealed that the stem depth at 1 month after total hip arthroplasty (odds ratio, 1.14; 95% confidence interval, 1.04-1.24, p = 0.002) was a significant and independent risk factor of postoperative callus.

Conclusion: Deep insertion of a short tapered-wedge stem is a risk factor for postoperative callus.

References
1.
Mirza A, Lombardi Jr A, Morris M, Berend K . A mini-anterior approach to the hip for total joint replacement: optimising results: improving hip joint replacement outcomes. Bone Joint J. 2014; 96-B(11 Supple A):32-5. DOI: 10.1302/0301-620X.96B11.34348. View

2.
Samy A, El-Tantawy A . Stem length in primary cementless total hip arthroplasty: Does it make a difference in bone remodeling?. Eur J Orthop Surg Traumatol. 2019; 29(6):1235-1242. DOI: 10.1007/s00590-019-02437-z. View

3.
Berend K, Mirza A, Morris M, Lombardi Jr A . Risk of Periprosthetic Fractures With Direct Anterior Primary Total Hip Arthroplasty. J Arthroplasty. 2016; 31(10):2295-8. DOI: 10.1016/j.arth.2016.03.007. View

4.
Tamaki T, Jonishi K, Miura Y, Oinuma K, Shiratsuchi H . Cementless Tapered-Wedge Stem Length Affects the Risk of Periprosthetic Femoral Fractures in Direct Anterior Total Hip Arthroplasty. J Arthroplasty. 2017; 33(3):805-809. DOI: 10.1016/j.arth.2017.09.065. View

5.
Harper K, Incavo S, Clyburn T . Short-Stem Prostheses in Total Hip Arthroplasty: An Unexpected Short-Term Complication: A Report of 2 Cases. JBJS Case Connect. 2020; 10(1):e0159. DOI: 10.2106/JBJS.CC.19.00159. View