6.
Slullitel P, Onativia J, Llano L, Comba F, Zanotti G, Piccaluga F
. Periprosthetic stress fracture around a well-fixed type 2B short uncemented stem. SICOT J. 2018; 4:33.
PMC: 6065269.
DOI: 10.1051/sicotj/2018031.
View
7.
Nandi S, Shah A, Joukar A, Becker K, Crutchfield C, Goel V
. Short single-wedge stems have higher risk of periprosthetic fracture than other cementless stem designs in Dorr type A femurs: a finite element analysis. Hip Int. 2020; 32(3):298-303.
DOI: 10.1177/1120700020949185.
View
8.
Baba T, Shitoto K, Kaneko K
. Bipolar hemiarthroplasty for femoral neck fracture using the direct anterior approach. World J Orthop. 2013; 4(2):85-9.
PMC: 3631957.
DOI: 10.5312/wjo.v4.i2.85.
View
9.
Yeung Y, Chiu K, Yau W, Tang W, Cheung W, Ng T
. Assessment of the proximal femoral morphology using plain radiograph-can it predict the bone quality?. J Arthroplasty. 2006; 21(4):508-13.
DOI: 10.1016/j.arth.2005.04.037.
View
10.
Abe H, Sakai T, Takao M, Nishii T, Nakamura N, Sugano N
. Difference in Stem Alignment Between the Direct Anterior Approach and the Posterolateral Approach in Total Hip Arthroplasty. J Arthroplasty. 2015; 30(10):1761-6.
DOI: 10.1016/j.arth.2015.04.026.
View
11.
Ishii S, Homma Y, Baba T, Ozaki Y, Matsumoto M, Kaneko K
. Does the Canal Fill Ratio and Femoral Morphology of Asian Females Influence Early Radiographic Outcomes of Total Hip Arthroplasty With an Uncemented Proximally Coated, Tapered-Wedge Stem?. J Arthroplasty. 2016; 31(7):1524-8.
DOI: 10.1016/j.arth.2016.01.016.
View
12.
Chan Y
. Biostatistics 104: correlational analysis. Singapore Med J. 2004; 44(12):614-9.
View
13.
Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P
. Uncemented total hip arthroplasty for primary osteoarthritis in young patients: a mid-to long-term follow-up study from the Finnish Arthroplasty Register. Acta Orthop. 2006; 77(1):57-70.
DOI: 10.1080/17453670610045704.
View
14.
Parvizi J, Keisu K, Hozack W, Sharkey P, Rothman R
. Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem. J Arthroplasty. 2004; 19(2):151-6.
DOI: 10.1016/j.arth.2003.10.003.
View
15.
Warth L, Grant T, Naveen N, Deckard E, Ziemba-Davis M, Meneghini R
. Inadequate Metadiaphyseal Fill of a Modern Taper-Wedge Stem Increases Subsidence and Risk of Aseptic Loosening: Technique and Distal Canal Fill Matter!. J Arthroplasty. 2020; 35(7):1868-1876.
DOI: 10.1016/j.arth.2020.02.024.
View
16.
Alpaugh K, Chiu Y, Zlotnicki J, Bendich I, Gonzalez Della Valle A, Bostrom M
. Femoral Component Undersizing and Alignment are Risk Factors for Early Periprosthetic Femur Fracture. J Arthroplasty. 2022; 37(7S):S604-S610.
DOI: 10.1016/j.arth.2022.03.015.
View
17.
Hoskins W, Rainbird S, Holder C, Stoney J, Graves S, Bingham R
. A Comparison of Revision Rates and Dislocation After Primary Total Hip Arthroplasty with 28, 32, and 36-mm Femoral Heads and Different Cup Sizes: An Analysis of 188,591 Primary Total Hip Arthroplasties. J Bone Joint Surg Am. 2022; 104(16):1462-1474.
DOI: 10.2106/JBJS.21.01101.
View
18.
Burroughs B, Muratoglu O, Bragdon C, Wannomae K, Christensen S, Lozynsky A
. In vitro comparison of frictional torque and torsional resistance of aged conventional gamma-in-nitrogen sterilized polyethylene versus aged highly crosslinked polyethylene articulating against head sizes larger than 32 mm. Acta Orthop. 2006; 77(5):710-8.
DOI: 10.1080/17453670610012881.
View
19.
Sariali E, Lazennec J, Khiami F, Catonne Y
. Mathematical evaluation of jumping distance in total hip arthroplasty: influence of abduction angle, femoral head offset, and head diameter. Acta Orthop. 2009; 80(3):277-82.
PMC: 2823207.
DOI: 10.3109/17453670902988378.
View
20.
Malik A, Maheshwari A, Dorr L
. Impingement with total hip replacement. J Bone Joint Surg Am. 2007; 89(8):1832-42.
DOI: 10.2106/JBJS.F.01313.
View