» Articles » PMID: 39010300

Deep Learning Enabled Universal Multiplexed Fluorescence Detection for Point-of-Care Applications

Overview
Journal ACS Sens
Specialty Biotechnology
Date 2024 Jul 16
PMID 39010300
Authors
Affiliations
Soon will be listed here.
Abstract

There is a significant demand for multiplexed fluorescence sensing and detection across a range of applications. Yet, the development of portable and compact multiplexable systems remains a substantial challenge. This difficulty largely stems from the inherent need for spectrum separation, which typically requires sophisticated and expensive optical components. Here, we demonstrate a compact, lens-free, and cost-effective fluorescence sensing setup that incorporates machine learning for scalable multiplexed fluorescence detection. This method utilizes low-cost optical components and a pretrained machine learning (ML) model to enable multiplexed fluorescence sensing without optical adjustments. Its multiplexing capability can be easily scaled up through updates to the machine learning model without altering the hardware. We demonstrate its real-world application in a probe-based multiplexed Loop-Mediated Isothermal Amplification (LAMP) assay designed to simultaneously detect three common respiratory viruses within a single reaction. The effectiveness of this approach highlights the system's potential for point-of-care applications that require cost-effective and scalable solutions. The machine learning-enabled multiplexed fluorescence sensing demonstrated in this work would pave the way for widespread adoption in diverse settings, from clinical laboratories to field diagnostics.

Citing Articles

Fully Automated and AI-Assisted Optical Fiber Sensing System for Multiplexed and Continuous Brain Monitoring.

Zhang Y, Zhang N, Hu Y, Pereira C, Fertleman M, Jiang N ACS Sens. 2024; 9(12):6605-6620.

PMID: 39629823 PMC: 11686509. DOI: 10.1021/acssensors.4c02126.

References
1.
Takayama I, Nakauchi M, Takahashi H, Oba K, Semba S, Kaida A . Development of real-time fluorescent reverse transcription loop-mediated isothermal amplification assay with quenching primer for influenza virus and respiratory syncytial virus. J Virol Methods. 2019; 267:53-58. PMC: 7113748. DOI: 10.1016/j.jviromet.2019.02.010. View

2.
Seo J, Sim Y, Kim J, Kim H, Cho I, Nam H . PICASSO allows ultra-multiplexed fluorescence imaging of spatially overlapping proteins without reference spectra measurements. Nat Commun. 2022; 13(1):2475. PMC: 9072354. DOI: 10.1038/s41467-022-30168-z. View

3.
Dincer C, Bruch R, Kling A, Dittrich P, Urban G . Multiplexed Point-of-Care Testing - xPOCT. Trends Biotechnol. 2017; 35(8):728-742. PMC: 5538621. DOI: 10.1016/j.tibtech.2017.03.013. View

4.
Johnson M, Wagstaffe H, Gilmour K, Mai A, Lewis J, Hunt A . Evaluation of a novel multiplexed assay for determining IgG levels and functional activity to SARS-CoV-2. J Clin Virol. 2020; 130:104572. PMC: 7396134. DOI: 10.1016/j.jcv.2020.104572. View

5.
Choi G, Prince T, Miao J, Cui L, Guan W . Sample-to-answer palm-sized nucleic acid testing device towards low-cost malaria mass screening. Biosens Bioelectron. 2018; 115:83-90. PMC: 6459019. DOI: 10.1016/j.bios.2018.05.019. View