Image Quality of Lung Perfusion with Photon-counting-detector CT: Comparison with Dual-source, Dual-energy CT

Overview
Journal Eur Radiol
Specialty Radiology
Date 2024 Jul 5
PMID 38967660
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To evaluate the quality of lung perfusion imaging obtained with photon-counting-detector CT (PCD-CT) in comparison with dual-source, dual-energy CT (DECT).

Methods: Seventy-one consecutive patients scanned with PCD-CT were compared to a paired population scanned with dual-energy on a 3rd-generation DS-CT scanner using (a) for DS-CT (Group 1): collimation: 64 × 0.6 × 2 mm; pitch: 0.55; (b) for PCD-CT (Group 2): collimation: 144 × 0.4 mm; pitch: 1.5; single-source acquisition. The injection protocol was similar in both groups with the reconstruction of perfusion images by subtraction of high- and low-energy virtual monoenergetic images.

Results: Compared to Group 1, Group 2 examinations showed: (a) a shorter duration of data acquisition (0.93 ± 0.1 s vs 3.98 ± 0.35 s; p < 0.0001); (b) a significantly lower dose-length-product (172.6 ± 55.14 vs 339.4 ± 75.64 mGy·cm; p < 0.0001); and (c) a higher level of objective noise (p < 0.0001) on mediastinal images. On perfusion images: (a) the mean level of attenuation did not differ (p = 0.05) with less subjective image noise in Group 2 (p = 0.049); (b) the distribution of scores of fissure visualization differed between the 2 groups (p < 0.0001) with a higher proportion of fissures sharply delineated in Group 2 (n = 60; 84.5% vs n = 26; 26.6%); (c) the rating of cardiac motion artifacts differed between the 2 groups (p < 0.0001) with a predominance of examinations rated with mild artifacts in Group 2 (n = 69; 97.2%) while the most Group 1 examinations showed moderate artifacts (n = 52; 73.2%).

Conclusion: PCD-CT acquisitions provided similar morphologic image quality and superior perfusion imaging at lower radiation doses.

Clinical Relevance Statement: The improvement in the overall quality of perfusion images at lower radiation doses opens the door for wider applications of lung perfusion imaging in clinical practice.

Key Points: The speed of data acquisition with PCD-CT accounts for mild motion artifacts. Sharply delineated fissures are depicted on PCD-CT perfusion images. High-quality perfusion imaging was obtained with a 52% dose reduction.

Citing Articles

Cardiothoracic Imaging for Outcome Prediction in Chronic Thromboembolic Pulmonary Hypertension after Pulmonary Endarterectomy or Balloon Pulmonary Angioplasty: A Scoping Review.

Malik M, Malik S, Karur G, Mafeld S, de Perrot M, McInnis M J Clin Med. 2024; 13(17).

PMID: 39274257 PMC: 11395896. DOI: 10.3390/jcm13175045.

References
1.
Grillet F, Busse-Cote A, Calame P, Behr J, Delabrousse E, Aubry S . COVID-19 pneumonia: microvascular disease revealed on pulmonary dual-energy computed tomography angiography. Quant Imaging Med Surg. 2020; 10(9):1852-1862. PMC: 7417764. DOI: 10.21037/qims-20-708. View

2.
Sawall S, Klein L, Amato C, Wehrse E, Dorn S, Maier J . Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Eur J Radiol. 2020; 126:108909. DOI: 10.1016/j.ejrad.2020.108909. View

3.
Thieme S, Graute V, Nikolaou K, Maxien D, Reiser M, Hacker M . Dual Energy CT lung perfusion imaging--correlation with SPECT/CT. Eur J Radiol. 2010; 81(2):360-5. DOI: 10.1016/j.ejrad.2010.11.037. View

4.
Pinilo J, Hutt A, Labreuche J, Faivre J, Flohr T, Schmidt B . Evaluation Of a New Reconstruction Technique for Dual-Energy (DECT) Lung Perfusion: Preliminary Experience In 58 Patients. Acad Radiol. 2021; 29 Suppl 2:S202-S214. DOI: 10.1016/j.acra.2021.07.023. View

5.
McCollough C, Rajendran K, Baffour F, Diehn F, Ferrero A, Glazebrook K . Clinical applications of photon counting detector CT. Eur Radiol. 2023; 33(8):5309-5320. PMC: 10330165. DOI: 10.1007/s00330-023-09596-y. View