Dual Energy CT Lung Perfusion Imaging--correlation with SPECT/CT

Overview
Journal Eur J Radiol
Specialty Radiology
Date 2010 Dec 28
PMID 21185141
Citations 47
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Aims were (1) to determine the diagnostic accuracy of Dual Energy CT (DECT) in the detection of perfusion defects and (2) to evaluate the potential of DECT to improve the sensitivity for PE.

Methods: 15 patients underwent Dual Energy pulmonary CT angiography (DE CTPA) and a combination of lung perfusion SPECT/CT and ventilation scintigraphy. CTPA and DE iodine distribution maps as well as perfusion SPECT/CT and inhalation scintigrams were reviewed for pulmonary embolism (PE) diagnosis. DECT and SPECT perfusion images were assessed regarding localization and extent of perfusion defects. Diagnostic accuracy of DE iodine (perfusion) maps was determined with reference to SPECT/CT. Diagnostic accuracies for PE detection of DECT and of SPECT/CT with ventilation scintigraphy were calculated with reference to the consensus reading of all modalities.

Results: DE CTPA had a sensitivity/specificity of 100%/100% for acute PE, while the combination of SPECT/CT and ventilation scintigraphy had a sensitivity/specificity of 85.7%/87.5%. For perfusion defects, DECT iodine maps had a sensitivity/specificity of 76.7% and 98.2%.

Conclusion: DECT is able to identify pulmonary perfusion defects with good accuracy. This technique may potentially enhance the diagnostic accuracy in the assessment of PE.

Citing Articles

Pulmonary emphysema: the assessment of lung perfusion with Dual-Energy CT and pulmonary scintigraphy.

Borgheresi A, Cesari E, Agostini A, Badaloni M, Balducci S, Tola E Radiol Med. 2024; 129(11):1622-1632.

PMID: 39256299 PMC: 11554815. DOI: 10.1007/s11547-024-01883-y.


Image quality of lung perfusion with photon-counting-detector CT: comparison with dual-source, dual-energy CT.

Remy-Jardin M, Guiffault L, Oufriche I, Duhamel A, Flohr T, Schmidt B Eur Radiol. 2024; 34(12):7831-7844.

PMID: 38967660 DOI: 10.1007/s00330-024-10888-0.


Head-to-Head Comparison of Dual-Source and Split-Beam Filter Multi-Energy CT versus SPECT/CT for Assessing Lobar Lung Perfusion in Emphysema.

Strotzer Q, Heidemanns S, Mayr V, Stuerzl R, Meiler S, Schmidt D Radiol Cardiothorac Imaging. 2023; 5(4):e220273.

PMID: 37693196 PMC: 10483249. DOI: 10.1148/ryct.220273.


Advances for Pulmonary Functional Imaging: Dual-Energy Computed Tomography for Pulmonary Functional Imaging.

Ozawa Y, Ohno Y, Nagata H, Tamokami K, Nishikimi K, Oshima Y Diagnostics (Basel). 2023; 13(13).

PMID: 37443688 PMC: 10340383. DOI: 10.3390/diagnostics13132295.


Characteristics of the deep learning-based virtual monochromatic image with fast kilovolt-switching CT: a phantom study.

Katsuyama Y, Kojima T, Shirasaka T, Kondo M, Kato T Radiol Phys Technol. 2022; 16(1):77-84.

PMID: 36583827 DOI: 10.1007/s12194-022-00695-x.