» Articles » PMID: 38753660

Development of a Multiplex Loop-Mediated Isothermal Amplification (LAMP) for the Diagnosis of Bacterial Periprosthetic Joint Infection

Overview
Journal PLoS One
Date 2024 May 16
PMID 38753660
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Periprosthetic joint infection (PJI) is one of the most serious and debilitating complications that can occur after total joint arthroplasty. Therefore, early diagnosis and appropriate treatment are important for a good prognosis. Recently, molecular diagnostic methods have been widely used to detect the causative microorganisms of PJI sensitively and rapidly. The Multiplex Loop-Mediated Isothermal Amplification (LAMP) method eliminates the complex temperature cycling and delays caused by temperature transitions seen in polymerase chain reaction (PCR) methods, making it faster and easier to perform compared to PCR-based assays. Therefore, this study developed a multiplex LAMP assay for diagnosing bacterial PJI using LAMP technology and evaluated its analytical and clinical performance.

Methods: We developed a multiplex LAMP assay for the detection of five bacteria: Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus agalactiae, Pseudomonas aeruginosa, and Escherichia coli, frequently observed to be the causative agents of PJI. The method of analytical sensitivity and cross-reactivity were determined by spiking standard strains into the joint synovial fluid. The analytical sensitivity of the multiplex LAMP assay was compared with that of a quantitative real-time PCR (qPCR) assay. Clinical performance was evaluated using 20 joint synovial fluid samples collected from patients suspected of having bacterial PJI.

Results: The analytical sensitivity of the gram-positive bacterial multiplex LAMP assay and qPCR were 105/104 CFU/mL, 103/103 CFU/mL, and 105/104 CFU/mL against S. agalactiae, S. epidermidis, and S. aureus, respectively. For P. aeruginosa and E. coli, the analytical sensitivity of the multiplex LAMP and qPCR assays were 105/104 and 106/104 CFU/mL, respectively. The multiplex LAMP assay detects target bacteria without cross-reacting with other bacteria, and exhibited 100% sensitivity and specificity in clinical performance evaluation.

Conclusions: This multiplex LAMP assay can rapidly detect five high-prevalence bacterial species causing bacterial PJI, with excellent sensitivity and specificity, in less than 1 h, and it may be useful for the early diagnosis of PJI.

Citing Articles

Novel Method for the Rapid Establishment of Antibiotic Susceptibility Profiles in Bacterial Strains Linked to Musculoskeletal Infections Using Scattered Light Integrated Collector Technology.

Bertheloot D, Nessler V, Assaf E, Amerschlager C, Ali K, Ossendorff R Int J Mol Sci. 2025; 26(4).

PMID: 40004019 PMC: 11855405. DOI: 10.3390/ijms26041553.


Molecular Detection of Respiratory Tract Viruses in Chickens at the Point of Need by Loop-Mediated Isothermal Amplification (LAMP).

El-Tholoth M, Bau H Viruses. 2024; 16(8).

PMID: 39205222 PMC: 11359210. DOI: 10.3390/v16081248.

References
1.
Benito N, Franco M, Ribera A, Soriano A, Rodriguez-Pardo D, Sorli L . Time trends in the aetiology of prosthetic joint infections: a multicentre cohort study. Clin Microbiol Infect. 2016; 22(8):732.e1-8. DOI: 10.1016/j.cmi.2016.05.004. View

2.
Vandercam B, Jeumont S, Cornu O, Yombi J, Lecouvet F, Lefevre P . Amplification-based DNA analysis in the diagnosis of prosthetic joint infection. J Mol Diagn. 2008; 10(6):537-43. PMC: 2570637. DOI: 10.2353/jmoldx.2008.070137. View

3.
Zimmerli W, Trampuz A, Ochsner P . Prosthetic-joint infections. N Engl J Med. 2004; 351(16):1645-54. DOI: 10.1056/NEJMra040181. View

4.
Xu Z, Li L, Chu J, Peters B, Harris M, Li B . Development and application of loop-mediated isothermal amplification assays on rapid detection of various types of staphylococci strains. Food Res Int. 2012; 47(2):166-173. PMC: 3390935. DOI: 10.1016/j.foodres.2011.04.042. View

5.
Bemer P, Plouzeau C, Tande D, Leger J, Giraudeau B, Valentin A . Evaluation of 16S rRNA gene PCR sensitivity and specificity for diagnosis of prosthetic joint infection: a prospective multicenter cross-sectional study. J Clin Microbiol. 2014; 52(10):3583-9. PMC: 4187742. DOI: 10.1128/JCM.01459-14. View