» Articles » PMID: 28578093

Direct Bacterial Loop-mediated Isothermal Amplification Detection on the Pathogenic Features of the Nosocomial Pathogen - Methicillin Resistant Staphylococcus Aureus Strains with Respiratory Origins

Overview
Journal Microb Pathog
Date 2017 Jun 5
PMID 28578093
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Loop-mediated isothermal amplification based detection assays using bacterial culture or colony for direct detection of methicillin resistant Staphylococcus aureus(MRSA) had been developed and evaluated, followed by its extensive application on a large scale of clinical MRSA isolated from respiratory origins, including nasal swabs and sputums. Six primers, including outer primers, inner primers and loop primers, were specifically designed for recognizing eight distinct sequences on four targets: 16SrRNA, femA, mecA and orfX. Twenty-seven reference strains were used to develop, evaluate and optimize this assay. Then, a total of 532 clinical MRSA isolates were employed for each detected targets. And the results were determined through both visual observation of the color change by naked eye and electrophoresis. The specific of each primer had been confirmed, and the optimal amplification was obtained under 65 °C for 40 min. The limit of detections (LOD) of bacteria culture LAMP assays were determined to be 10 CFU/ml for 16S rRNA, femA, as well as orfX and 10 CFU/ml for mecA, respectively. The established novel assays on MRSA detection may provide new strategies for rapid detection of foodborne pathogens.

Citing Articles

Triple-Branch Catalytic Assembly DNAzyme Motivated DNA Tweezer for Sensitive and Reliable Gene Detection in .

Li X, Xu M, Gan F, Zhao H J Microbiol Biotechnol. 2024; 34(12):2450-2456.

PMID: 39467691 PMC: 11729337. DOI: 10.4014/jmb.2409.09008.


Development of a multiplex Loop-Mediated Isothermal Amplification (LAMP) for the diagnosis of bacterial periprosthetic joint infection.

Jang W, Park S, Bae J, Yoon S, Lim C, Cho M PLoS One. 2024; 19(5):e0302783.

PMID: 38753660 PMC: 11098349. DOI: 10.1371/journal.pone.0302783.


Exonuclease-III Assisted the Target Recycling Coupling with Hybridization Chain Reaction for Sensitive mecA Gene Analysis by Using PGM.

Du Y, Xiu N Appl Biochem Biotechnol. 2024; 196(10):6716-6725.

PMID: 38401042 DOI: 10.1007/s12010-024-04862-1.


Feasibility of Loop-Mediated Isothermal Amplification for Rapid Detection of Methicillin-Susceptible and Methicillin-Resistant in Tissue Samples.

Kim S, Choi G, Choi W, Lim C, Jang W, Bae J Clin Orthop Surg. 2022; 14(3):466-473.

PMID: 36061848 PMC: 9393274. DOI: 10.4055/cios21277.


Loop-Mediated Isothermal Amplification (LAMP) as a Rapid, Affordable and Effective Tool to Involve Students in Undergraduate Research.

Nguyen A, Orlofsky A, Pubill K, Tawde M, Li G, Mata D Front Microbiol. 2020; 11:603381.

PMID: 33362748 PMC: 7756096. DOI: 10.3389/fmicb.2020.603381.