Leveraging Temporal Information to Improve Machine Learning-Based Calibration Techniques for Low-Cost Air Quality Sensors

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2024 May 11
PMID 38733036
Authors
Affiliations
Soon will be listed here.
Abstract

Low-cost ambient sensors have been identified as a promising technology for monitoring air pollution at a high spatio-temporal resolution. However, the pollutant data captured by these cost-effective sensors are less accurate than their conventional counterparts and require careful calibration to improve their accuracy and reliability. In this paper, we propose to leverage temporal information, such as the duration of time a sensor has been deployed and the time of day the reading was taken, in order to improve the calibration of low-cost sensors. This information is readily available and has so far not been utilized in the reported literature for the calibration of cost-effective ambient gas pollutant sensors. We make use of three data sets collected by research groups around the world, who gathered the data from field-deployed low-cost CO and NO sensors co-located with accurate reference sensors. Our investigation shows that using the temporal information as a co-variate can significantly improve the accuracy of common machine learning-based calibration techniques, such as Random Forest and Long Short-Term Memory.

References
1.
Zuidema C, Schumacher C, Austin E, Carvlin G, Larson T, Spalt E . Deployment, Calibration, and Cross-Validation of Low-Cost Electrochemical Sensors for Carbon Monoxide, Nitrogen Oxides, and Ozone for an Epidemiological Study. Sensors (Basel). 2021; 21(12). PMC: 8234435. DOI: 10.3390/s21124214. View

2.
Kampa M, Castanas E . Human health effects of air pollution. Environ Pollut. 2007; 151(2):362-7. DOI: 10.1016/j.envpol.2007.06.012. View

3.
Zhu J, Wu P, Chen H, Zhou L, Tao Z . A Hybrid Forecasting Approach to Air Quality Time Series Based on Endpoint Condition and Combined Forecasting Model. Int J Environ Res Public Health. 2018; 15(9). PMC: 6164777. DOI: 10.3390/ijerph15091941. View

4.
Balabin R, Lomakina E . Support vector machine regression (SVR/LS-SVM)--an alternative to neural networks (ANN) for analytical chemistry? Comparison of nonlinear methods on near infrared (NIR) spectroscopy data. Analyst. 2011; 136(8):1703-12. DOI: 10.1039/c0an00387e. View

5.
Rogulski M, Badyda A, Gayer A, Reis J . Improving the Quality of Measurements Made by Alphasense NO Non-Reference Sensors Using the Mathematical Methods. Sensors (Basel). 2022; 22(10). PMC: 9144097. DOI: 10.3390/s22103619. View