» Articles » PMID: 38732829

Improving the Signal-to-Noise Ratio of Axial Displacement Measurements of Microspheres Based on Compound Digital Holography Microscopy Combined with the Reconstruction Centering Method

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2024 May 11
PMID 38732829
Authors
Affiliations
Soon will be listed here.
Abstract

In 3D microsphere tracking, unlike in-plane motion that can be measured directly by a microscope, axial displacements are resolved by optical interference or a diffraction model. As a result, the axial results are affected by the environmental noise. The immunity to environmental noise increases with measurement accuracy and the signal-to-noise ratio (SNR). In compound digital holography microscopy (CDHM)-based measurements, precise identification of the tracking marker is critical to ensuring measurement precision. The reconstruction centering method (RCM) was proposed to suppress the drawbacks caused by installation errors and, at the same time, improve the correct identification of the tracking marker. The reconstructed center is considered to be the center of the microsphere, rather than the center of imaging in conventional digital holographic microscopy. This method was verified by simulation of rays tracing through microspheres and axial moving experiments. The axial displacements of silica microspheres with diameters of 5 μm and 10 μm were tested by CDHM in combination with the RCM. As a result, the SNR of the proposed method was improved by around 30%. In addition, the method was successfully applied to axial displacement measurements of overlapped microspheres with a resolution of 2 nm.

References
1.
Wang Z, Guo W, Li L, Lukyanchuk B, Khan A, Liu Z . Optical virtual imaging at 50 nm lateral resolution with a white-light nanoscope. Nat Commun. 2011; 2:218. DOI: 10.1038/ncomms1211. View

2.
Go T, Kim J, Lee S . Three-dimensional volumetric monitoring of settling particulate matters on a leaf using digital in-line holographic microscopy. J Hazard Mater. 2020; 404(Pt A):124116. DOI: 10.1016/j.jhazmat.2020.124116. View

3.
Panahi M, Jamali R, Rad V, Khorasani M, Darudi A, Moradi A . 3D monitoring of the surface slippage effect on micro-particle sedimentation by digital holographic microscopy. Sci Rep. 2021; 11(1):12916. PMC: 8217179. DOI: 10.1038/s41598-021-92498-0. View

4.
Chen H, Fu H, Zhu X, Cong P, Nakamura F, Yan J . Improved high-force magnetic tweezers for stretching and refolding of proteins and short DNA. Biophys J. 2011; 100(2):517-23. PMC: 3325116. DOI: 10.1016/j.bpj.2010.12.3700. View

5.
Zeng Y, Chang X, Lei H, Hu X, Hu X . Characteristics analysis of digital image-plane holographic microscopy. Scanning. 2015; 38(4):288-96. DOI: 10.1002/sca.21268. View