» Articles » PMID: 38692199

Motion Correction and Super-resolution for Multi-slice Cardiac Magnetic Resonance Imaging Via an End-to-end Deep Learning Approach

Overview
Specialty Radiology
Date 2024 May 1
PMID 38692199
Authors
Affiliations
Soon will be listed here.
Abstract

Accurate reconstruction of a high-resolution 3D volume of the heart is critical for comprehensive cardiac assessments. However, cardiac magnetic resonance (CMR) data is usually acquired as a stack of 2D short-axis (SAX) slices, which suffers from the inter-slice misalignment due to cardiac motion and data sparsity from large gaps between SAX slices. Therefore, we aim to propose an end-to-end deep learning (DL) model to address these two challenges simultaneously, employing specific model components for each challenge. The objective is to reconstruct a high-resolution 3D volume of the heart (V) from acquired CMR SAX slices (V). We define the transformation from V to V as a sequential process of motion correction and super-resolution. Accordingly, our DL model incorporates two distinct components. The first component conducts motion correction by predicting displacement vectors to re-position each SAX slice accurately. The second component takes the motion-corrected SAX slices from the first component and performs the super-resolution to fill the data gaps. These two components operate in a sequential way, and the entire model is trained end-to-end. Our model significantly reduced inter-slice misalignment from originally 3.33±0.74 mm to 1.36±0.63 mm and generated accurate high resolution 3D volumes with Dice of 0.974±0.010 for left ventricle (LV) and 0.938±0.017 for myocardium in a simulation dataset. When compared to the LAX contours in a real-world dataset, our model achieved Dice of 0.945±0.023 for LV and 0.786±0.060 for myocardium. In both datasets, our model with specific components for motion correction and super-resolution significantly enhance the performance compared to the model without such design considerations. The codes for our model are available at https://github.com/zhennongchen/CMR_MC_SR_End2End.

Citing Articles

Hypertrophic obstructive cardiomyopathy-left ventricular outflow tract shapes and their hemodynamic influences applying CMR.

Mayr T, Riazy L, Trauzeddel R, Bassenge J, Wiesemann S, Blaszczyk E Int J Cardiovasc Imaging. 2024; 40(11):2371-2381.

PMID: 39302632 PMC: 11561129. DOI: 10.1007/s10554-024-03242-4.

References
1.
de Marvao A, Dawes T, Shi W, Minas C, Keenan N, Diamond T . Population-based studies of myocardial hypertrophy: high resolution cardiovascular magnetic resonance atlases improve statistical power. J Cardiovasc Magn Reson. 2014; 16:16. PMC: 3914701. DOI: 10.1186/1532-429X-16-16. View

2.
Banerjee A, Camps J, Zacur E, Andrews C, Rudy Y, Choudhury R . A completely automated pipeline for 3D reconstruction of human heart from 2D cine magnetic resonance slices. Philos Trans A Math Phys Eng Sci. 2021; 379(2212):20200257. PMC: 8543046. DOI: 10.1098/rsta.2020.0257. View

3.
Zhang H, Wahle A, Johnson R, Scholz T, Sonka M . 4-D cardiac MR image analysis: left and right ventricular morphology and function. IEEE Trans Med Imaging. 2009; 29(2):350-64. PMC: 2849009. DOI: 10.1109/TMI.2009.2030799. View

4.
Yang D, Wu P, Tan C, Pohl K, Axel L, Metaxas D . 3D Motion Modeling and Reconstruction of Left Ventricle Wall in Cardiac MRI. Funct Imaging Model Heart. 2017; 10263:481-492. PMC: 5484578. DOI: 10.1007/978-3-319-59448-4_46. View

5.
Alba X, Pereanez M, Hoogendoorn C, Swift A, Wild J, Frangi A . An Algorithm for the Segmentation of Highly Abnormal Hearts Using a Generic Statistical Shape Model. IEEE Trans Med Imaging. 2015; 35(3):845-59. DOI: 10.1109/TMI.2015.2497906. View