» Articles » PMID: 38614998

Does a Novel 3D Printed Individualized Guiding Template Based on Cutaneous Fiducial Markers Contribute to Accurate Percutaneous Insertion of Pelvic Screws? A Preliminary Phantom and Cadaver Study

Overview
Journal BMC Surg
Publisher Biomed Central
Specialty General Surgery
Date 2024 Apr 13
PMID 38614998
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Most 3D-printed guiding templates require dissection of soft tissues to match the corresponding surfaces of the guiding templates. This study sought to explore the accuracy and acceptability of the novel 3D printed individualized guiding templates based on cutaneous fiducial markers in minimally invasive screw placement for pelvic fractures.

Methods: The printed template was tested on five high-fidelity biomimetic phantom models of the bony pelvis and its surrounding soft tissues as well as on two fresh frozen cadavers. Four cutaneous fiducial markers were transfixed on each phantom model prior to performing CT scans to reconstruct their 3D models. Personalized templates for guiding screw insertion were designed based on the positions of the fiducial markers and virtually planned target screw channels after scanning, followed by 3D printing of the guide. Phase 1 consisted of five expert surgeons inserting one anterograde supra-pubic screw and one sacroiliac screw percutaneously into each phantom model using the 3D-printed guide. The deviation of screw positions between the pre-operative planned and post-operative actual ones was measured after registering their 3D modelling. A Likert scale questionnaire was completed by the expert surgeons to assess their satisfaction and acceptability with the guiding template. Phase 2 consisted of repeating the same procedures on the fresh frozen cadavers in order to demonstrate face, content and concurrent validity.

Results: In Phase 1, all ten screws were successfully implanted with the assistance of the guiding template. Postoperative CT scans confirmed that all screws were safely positioned within the bony pelvic channels without breaching the far cortex. The mean longitudinal deviation at the bony entry point and screw tip between the pre-operative planned and post-operative actual screw paths were 2.83 ± 0.60 mm and 3.12 ± 0.81 mm respectively, with a mean angular deviation of 1.25 ± 0.41°. Results from the Likert questionnaire indicated a high level of satisfaction for using the guiding template among surgeons. In Phase 2, results were similar to those in Phase 1.

Conclusions: The 3D-printed guiding template based on cutaneous fiducial markers shows potential for assisting in the accurate insertion of percutaneous screws in the pelvis.

References
1.
Zhang R, Yin Y, Li S, Guo J, Hou Z, Zhang Y . Sacroiliac screw versus a minimally invasive adjustable plate for Zone II sacral fractures: a retrospective study. Injury. 2019; 50(3):690-696. DOI: 10.1016/j.injury.2019.02.011. View

2.
Chen B, Zhang Y, Xiao S, Gu P, Lin X . Personalized image-based templates for iliosacral screw insertions: a pilot study. Int J Med Robot. 2012; 8(4):476-82. DOI: 10.1002/rcs.1453. View

3.
Yang F, Yao S, Chen K, Zhu F, Xiong Z, Ji Y . A novel patient-specific three-dimensional-printed external template to guide iliosacral screw insertion: a retrospective study. BMC Musculoskelet Disord. 2018; 19(1):397. PMC: 6234543. DOI: 10.1186/s12891-018-2320-3. View

4.
Kaneyama S, Sugawara T, Sumi M, Higashiyama N, Takabatake M, Mizoi K . A novel screw guiding method with a screw guide template system for posterior C-2 fixation: clinical article. J Neurosurg Spine. 2014; 21(2):231-8. DOI: 10.3171/2014.3.SPINE13730. View

5.
Hoskins W, Bucknill A, Wong J, Britton E, Judson R, Gumm K . A prospective case series for a minimally invasive internal fixation device for anterior pelvic ring fractures. J Orthop Surg Res. 2016; 11(1):135. PMC: 5101701. DOI: 10.1186/s13018-016-0468-9. View